Chapter 2, Making Measurements
Modulation Quality (Rho)
Steps | 1 | Connect the equipment as shown in figure 8. |
| 2 | In the main menu, enter the Base Station Channel number for the transmitter |
|
| being tested. |
| 3 | Also in the main menu, enter the Base Station PN Offset. |
| 4 | Set up the base station to transmit (pilot only) on the channel number entered in step 2. |
| 5 | Verify that the REF UNLOCK light on the front of the Cellular Adapter is not lit. |
| 6 | Scroll to and select Measure Rho Parameters screen (see figure 9). |
| 7 | Read the value under the Rho field. |
| 8 | Read the values after the Time offset, Freq error, and Carrier ft fields. |
| 9 | Press the Main Menu (k5) key to return to the main menu. |
Figure 9
Notes | If the message CANNOT CORRELATE appears on the screen, see "CDMA |
| Measurement not Correlating" in chapter 4, "Troubleshooting, on page 69." |
| For an |
| Diagnose (k4) key. |
29