Chapter 4, Troubleshooting
Errors When Loading and Running the Software
Test System
Configuration
Errors at Runtime
Problem:
When it is first run, the Software checks to see that all required elements of a CDMA/PCS Test System are present. If it does not find a CDMA Cellular Adapter or a PCS Interface, it will report the following errors:
This error will be reported if the Software cannot “find” the CDMA Cellular Adapter as an installed option on the Test Set.
Solution:
1Make sure that your are using either the HP 83203B or HP 83205A CDMA Cellular Adapter in your Test System.
2Verify that you have supplied the Cellular Adapter with AC power. The
3If the unit is powered on and you still get this message, you will need to check the rear- panel connections between the Test Set and Cellular Adapter, especially the CONTROL I/O cable between the two units. Refer to the Installation chapter of the Cellular Adapter’s manual for connections.
Verify PCS Interface is connected and on. Retry?:
This error will be reported if the Software cannot “find” the HP 83236B PCS Interface on the
Solution:
1Verify that you have supplied the PCS Interface with AC power and that the POWER switch is on. The
2If the unit is powered on and you still get this message, check the
3Confirm that the
66