Frame Error Rate (Receiver Measurements)
Chapter 4, Troubleshooting
Errors While Attempting Measurements
Problem:
If your Test System is not set up correctly for receiver tests, you may see erroneous results (extremely high FER or the inability to return a measurement) on the tool you use for displaying the Frame Error Rate calculated by the base station.
The error can occur while using the following menu screen:
•CDMA Generator Menu Selection
Possible causes and solutions:
1Missing an
You must have access to the
2Test System timebase reference not connected.
Verify that you have access to the base station’s reference timebase signal (typically 19.6608 MHz). The reference should be connected to the SYNTH REF IN port on the rear of the Cellular Adapter. If configured correctly, the REF UNLOCK indicator on the Cellular Adapter should not be on.
3Missing or faulty connections from the PCS Interface output to the receiver inputs of the base station.
Check to see that the RF IN/OUT port of the PCS Interface is connected to the receiver test port of the base station being tested.
4Incorrect Base Station Channel entry.
The Software tunes the CDMA Generator to a receive frequency based on your entry for Base Station Channel. The entry must match the channel your base station is set to receive on. Verify the channel number entry in the Base Station Channel field on the main menu screen. If you want to verify the frequency the Generator is set to, see the Generator Frequency setting at the bottom of the main menu screen.
71