Chapter 3, Operating Overview
An Alternative
An Alternative
| Chapter 1 describes the most common method of connecting timebases between |
| the Test System and the |
| way of connecting the timebases using the CDMA TIMEBASE IN port of the |
| CDMA Cellular Adapter (rather than the |
Steps | 1 Connect the timebases as shown in figure 25. Note the connections from the BNC “tee” |
| on the Test Set’s 10 MHz REF OUTPUT to both the Cellular Adapter and the PCS |
| Interface. |
|
|
NOTE: | This figure does not illustrate all |
| Test Set. Refer to the Cellular Adapter User’s Guide to verify these connections. |
|
|
2From the main menu, select Configuration Information Menu.
3Note the selection for the Base Station Reference To field. If it is set to SYNTH REF IN, scroll down to the line and press the knob to change it to read CDMA TB IN. Otherwise, you may skip this step.
4Note the selection for Base Station Reference Freq. If it does not match the timebase frequency supplied by the base station (typically 19.6608 MHz or
10 MHz), scroll to the line, press the knob, and select the appropriate value.
5To return to the main menu, press the Main Menu (k5) key.
Notes | The timebase settings you made in the steps above will not be saved unless you |
| use the Save Info to Memory feature. See "Saving Configuration Information |
| to Memory" on page 54. |
60