HP 449298-001 manual Fabric

Page 16

Item

Description

Examples:

->set external-manager UserName=steve Enabled=false

Disables the external manager

->set external-manager UserName=steve Enabled=true

Enables the external manager

fabric

Manage Fibre Channel SAN fabrics.

Support actions: help, set, show

Item

Description

 

 

set fabric

Modify an existing FC SAN fabric

 

 

Syntax

set fabric <FabricName> [Name=<NewName>] [NumPorts=<124>]

 

[PortSpeed=<Auto2Gb4Gb>]

 

 

Parameters:

 

 

 

FabricName

The name of an existing FC SAN fabric to modify (required)

 

 

Properties:

 

 

 

Name

The new name of the fabric

 

 

NumPorts

The number of uplink ports to use for the fabric

 

 

PortSpeed

The port speed for the uplink ports in the fabric

 

 

Examples:

 

 

 

 

->set fabric MyFabric NumPorts=2

 

Changes the number of ports used by the fabric

 

 

 

->set fabric Blue Name=Red

 

Changes the name of an existing fabric from "Blue" to "Red"

 

 

 

->set fabric GreenFabric PortSpeed=4Gb

 

Changes the port speed of the uplinks in a fabric

 

 

Item

Description

 

 

show fabric

Display all FC SAN fabrics

 

 

Syntax

show fabric [<FabricName> *]

 

 

Examples:

 

 

 

 

->show fabric

 

Displays a summary listing of all FC SAN fabrics

 

 

 

->show fabric *

 

Displays detailed information for all FC SAN fabrics

 

 

 

->show fabric SAN_5

 

Displays detailed information for a specific FC SAN fabric

 

 

Command line 16

Image 16
Contents HP Virtual Connect Manager Command Line Interface User Guide Audience assumptions Contents Technical support Introduction Command line overviewVirtual Connect overview Command line syntax Subcommand managed element parameters options propertiesParameters OptionsCLI command execution modes PropertiesRemote access to the Virtual Connect Manager Subcommands Command lineManaged elements Devicebay DomainSupported actions delete, help, set, show Enclosure Enet-connection Supported actions add, help, remove, setNetwork=SomeNetwork2 PXE=enabled AddressType=Factory-DefaultAddressType EthernetMACExternal-manager Fabric Fc-connection Support actions help, show, update FirmwareIgmp InterconnectLdap Ldap-group Supported actions add, help, remove, set, showMac-cache Network Profile Add profile MyNewProfile2 -NoDefaultEnetConn Add profile MyNewProfile2 -NoDefaultFcConnAdd profile MyNewProfile Assign profileSupported actions help, poweroff, poweron, reboot, show ServerPoweroff server enc02 Poweroff server enc02 -ForcePoweroff server enc0 Poweroff server enc02 -ForceOnTimeoutStackinglink Systemlog StatusUplinkport Set uplinkport Set uplinkport PortID Network=NetworkNameSpeed=Auto10Mb100Mb1GbDisabled Set uplinkport enc012 Network=MyNetwork Speed=1GbUplinkset User Set user steve Password=fgY87hHl Set user steve PasswordSet user bill Password=HGtwf7272562 Remove user steveVcm Help subsystemVersion Command line Output format Interactive user output formatBrad Domain Brad Mills Brad.mills@hp.com True Server Scriptable output format Command line Configuring the Virtual Connect domain using the CLI Basic configurationSsh 192.168.0.120 login as Administrator password Ssh 192.168.0.120 login as AdministratorDomain setup Setting the domain nameConfiguring local users Importing an enclosureAdd user bob password=fhkjdhfk privileges=domain,network Set user bob fullname=Bob J Smith enabled=falseRemove user bob Remove userConfiguring Ldap authentication support for users Network setupConfiguring MAC Address ranges Assigned MAC addresses Adding uplink ports to an enet-network Creating an enet-networkCreating a shared uplink port set Fibre Channel setup Configuring WWN address rangesAdding uplink ports to a shared uplink port set Creating a network that uses a shared uplink port setServer Profile setup Modifying FC fabric propertiesDisplaying FC fabrics Set fabric name=MyNewName portspeed=4GbConfiguring the Virtual Connect domain using the CLI Configuring Igmp settings Creating server profilesAdding enet-network connections to a profile Adding FC fabric connections to a server profileConfiguring MAC cache failover settings Set mac-cache enabled=true refresh=10Common management operations Logging out of the CLIResetting the Virtual Connect Manager Reset vcm Reset vcm -failoverVirtual Connect Manager not found at this IP address Before you contact HP Technical supportHP contact information Acronyms and abbreviations IgmpPXE Index Index