Because VLAN tags are added or removed when Ethernet packets leave or enter the
IMPORTANT: If you are deploying a server where VLAN tags will be used (added) on the server itself, do not connect the server Ethernet port carrying
Identifying an associated network as the native VLAN causes all untagged incoming Ethernet packets to be placed onto this network. Only one associated network can be designated as the native VLAN. All out- going Ethernet packets are VLAN tagged.
Displaying shared uplink port sets
•Summary display
>show uplinkset
•Detailed display
>show uplinkset *
•Single uplinkset display
>show uplinkset MyUplinkSetName
Adding uplink ports to a shared uplink port set
To add uplink ports to a shared uplink port set, use the add uplinkport command:
>add uplinkport enc0:1:2 uplinkset=MyUplinkSetName
Creating a network that uses a shared uplink port set
To create a network that uses a shared uplink port set, use the add network command:
>add network MyNewNetworkName uplinkset=MyUplinkSetName vlanid=156
Fibre Channel setup
To configure external Fibre Channel connectivity for the HP BladeSystem
1.Identify WWNs to be used on the server blades deployed within this Virtual Connect Domain.
2.Define available SAN fabrics.
Configuring WWN address ranges
•
>set domain
•
>set domain WwnType=Factory-Default
Each server blade FC HBA mezzanine card ships with factory default port and node WWNs for each FC HBA port. Each WWN is a
Configuring the Virtual Connect domain using the CLI 46