B.22 GROUPPOSAVE Configure Group Position Averaging

The groupposave command allows you to configure position averaging to commence when the group is executed. groupfixpos and groupposave configurations are mutually exclusive, and the last setting to be entered takes effect.

The groupposave set command configures the group for position-averaging with parameters set to maxtime, maxhorstd and maxverstd.

The groupposave clear and default commands clear the group position-average configuration.

Syntax

groupposave set groupname [maxtime [maxhorstd maxverstd]]

groupposave defaultclear groupname

B.22.1 Groupuse Translation

groupuse start

If position averaging is configured in the group, the posave command is executed with averaging time, maximum horizontal and vertical standard deviation set to the configured values.

groupuse stop

If position averaging is configured in the group, this command cancels it and issues a fix none command.

Message ID = 63

Field

Data

Value Used if

Bytes

Format

Units

Offset

Not Specified

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Header

-

 

-

-

0

 

 

 

 

 

 

 

2

Parameter Update, see Table 34 on

-

4

Enum

none

H

 

Page 107

 

 

 

 

 

 

 

 

 

 

 

 

3

Group name

-

12

Char[]

none

H+4

 

 

 

 

 

 

 

4

Maximum time

0

8

Double

hours

H+16

 

 

 

 

 

 

 

5

Maximum horizontal standard deviation

0

8

Double

none

H+24

 

 

 

 

 

 

 

6

Maximum vertical standard deviation

0

8

Double

none

H+32

 

 

 

 

 

 

 

Table 41: GROUPSAVE Default Configuration

Parameter

Power-On

 

Freset

Stored in NVM

maxtime

no change

0.01

 

YES

maxhorstd

no change

0

 

YES

maxverstd

no change

0

 

YES

114

DL-V3 User Manual Rev 3

Page 114
Image 114