DL-V3 User Manual Rev 3 137
B.37 SITEUPDATENUMBER Set Occupied Site Number
The siteupdatenumber command allows you to configure the site number information (SiteNumber
field in the sitedef log) once the site has been occupied (by issuing a site enter command).
The siteupdatenumber set command sets the site number for an occupied site to sitenumber.
The siteupdatenumber default and the siteupdatenumber clear commands clear the site number for an
occupied site.
The siteupdatenumber clear command clears the site number for an occupied site.
Syntax
siteupdatenumber set [sitenumber]
siteupdatenumber default|clear
Message ID = 171
Table 58: SITEUPDATENUMBER Default Configuration
Field Data Value Used if
Not Specified Bytes Format Units Offset
1 Header - - - 0
2 Parameter Update, see
Table 34 on Page 107 - 4 Enum none H
3 Site number NUL 8 Char[] none H+4
4 Reserved for future use NUL 12 Char[] none H+12
Parameter Power-On Freset Stored in NVM
Site Number clear clear NO