Message ID = 755

Field

Field Type

Bytes

Format

Units

Offset

 

 

 

 

 

 

1

Header

-

-

 

0

 

 

 

 

 

 

2

Parameter update, see Table 30

4

Enum

-

H

 

 

 

 

 

 

3

Group name

12

Char[ ]

-

H+4

 

 

 

 

 

 

4

Port to configure.

4

Enum

-

H+16

 

(default = THISPORT)

 

 

 

 

 

See Table 17 on Page 87

 

 

 

 

 

 

 

 

 

 

5

;Communication baud rate (bps).

4

ULong

bps

H+20

 

A value of '0' indicates that no

 

 

 

 

 

GROUPCOMCONFIG specification is associated

 

 

 

 

 

with the port for the specified group.

 

 

 

 

 

Possible bps values:

 

 

 

 

 

300, 600, 900, 1200, 2400, 4800, 9600, 19200,

 

 

 

 

 

38400, 57600, 115200, or 230400

 

 

 

 

 

 

 

 

 

 

6

Parity

4

Enum

-

H+24

 

See Table 31 on Page 102

 

 

 

 

 

 

 

 

 

 

7

Number of data bits 7 or 8

4

ULong

-

H+28

 

(default = 8)

 

 

 

 

 

 

 

 

 

 

8

Number of stop bits 1 or 2

4

ULong

-

H+32

 

(default = 1)

 

 

 

 

 

 

 

 

 

 

9

Handshaking

4

Enum

-

H+36

 

See Table 32 on Page 102

 

 

 

 

 

 

 

 

 

 

10

Echo

4

Enum

-

H+40

 

0 = Off - No echo

 

 

 

 

 

1 = On (default) - Transmit any input characters as

 

 

 

 

 

they are received

 

 

 

 

 

 

 

 

 

 

11

Break

4

Enum

-

H+44

 

0 = Off - Disable break detection

 

 

 

 

 

1 = On (default) - Enable break detection

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 30: Parameter Update

 

 

 

 

 

 

 

 

Binary

ASCII

 

Description

 

 

 

 

 

 

 

 

0

DEFAULT

 

Set the parameter for a group to the default (default)

 

 

 

 

 

 

 

 

1

SET

 

Set parameter for a the group

 

 

 

 

 

 

 

 

2

CLEAR

 

Clear a parameter from the group

 

 

 

 

 

 

 

 

 

 

 

 

 