B.29 METHUMID Specify Air Humidity

The methumid command allows you to specify air humidity. Humidity specified with the methumid command does not affect receiver operation. Rather, it allows you to create a record of atmospheric conditions for post-processing purposes.

The methumid set command specifies air humidity at humid. This command only stores the humidity value in volatile memory, and does not automatically generate a record. The humidity value can then be displayed/recorded by requesting the met log.

The methumid clear and the methumid default commands clear the humidity setting.

Syntax

methumid set [humid] methumid defaultclear

Message ID = 163

Field

Data

Value Used if

Bytes

Format

Units

Offset

Not Specified

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Header

-

 

-

-

0

 

 

 

 

 

 

 

2

Parameter Update, see

-

4

Enum

none

H

 

Table 34 on Page 107

 

 

 

 

 

 

 

 

 

 

 

 

3

Humidity

0

4

Float

percent

H+4

 

 

 

 

 

 

 

Table 49: METHUMID Default Configuration

Parameter

Power-On

Freset

Stored in NVM

 

 

 

 

methumid

clear

clear

NO

 

 

 

 

DL-V3 User Manual Rev 3

127

Page 127
Image 127
Novatel DL-V3 user manual Methumid Specify Air Humidity, Methumid Default Configuration