Operation

Chapter 3

PASSXCOM2, PASSXCOM3, PASSUSB1, PASSUSB2, PASSUSB3 and PASSAUX are available on OEMV family receivers for logging through serial ports. The AUX port is available on OEMV-3- based products. Refer to the PASSCOMx log for details.

3.8T Sync Option

The T Sync Option section of the OEMV Installation and Operation User Manual describes the relationship constraints of the input signal phase when the Time Synchronization Modification (T Sync Mod) option has been added to an OEMV-3-based product (this includes DL-V3).

When an external oscillator is connected, T Sync pulses are sent through hardware on the receiver card and cannot be disabled. You must issue a time-synchronization-enabling command (refer to ADJUST1PPS TIME in the OEMV Family Firmware Reference Manual) for the receiver to track properly.