8-4Troubleshooting

Error Code

Description of Error Condition

 

 

15H

Local channel configuration parameter error exists.

 

 

16H

Target or Local Bridge address is higher than the maximum node address.

 

 

17H

Local service is not supported.

 

 

18H

Broadcast is not supported.

 

 

21H

Bad MSG file parameter for building message.

 

 

30H

PCCC Description: Remote station host is not there, disconnected, or shutdown.

 

 

37H

Message timed out in local processor.

 

 

39H

Local communication channel reconfigured while MSG active.

 

 

3AH

STS in the reply from target is invalid.

 

 

40H

PCCC Description: Host could not complete function due to hardware fault.

 

 

45H

MSG reply cannot be processed. Either Insufficient data in MSG read reply or bad network address parameter.

 

 

50H

Target node is out of memory.

 

 

60H

Target node cannot respond because file is protected.

 

 

70H

PCCC Description: Processor is in Program Mode.

 

 

80H

PCCC Description: Compatibility mode file missing or communication zone problem.

 

 

90H

PCCC Description: Remote station cannot buffer command.

 

 

B0H

PCCC Description: Remote station problem due to download.

 

 

C0H

PCCC Description: Cannot execute command due to active IPBs.

 

 

D0H

One of the following:

 

No IP address configured for the network or ENI not configured for Node Address used.

 

Bad command - unsolicited message error.

 

Bad address - unsolicited message error.

 

No privilege - unsolicited message error.

 

 

D1H

Maximum connections used - no connections available.

 

 

D2H

Invalid internet address or host name.

 

 

D3H

No such host / Cannot communicate with the name server.

 

 

D4H

Connection not completed before user–specified timeout.

 

 

D5H

Connection timed out by the network.

 

 

D7H

Connection refused by destination host.

 

 

D8H

Connection was broken.

 

 

D9H

Reply not received before user–specified timeout.

 

 

DAH

No network buffer space available.

 

 

E1H

PCCC Description: Illegal Address Format, a field has an illegal value.

 

 

E2H

PCCC Description: Illegal Address format, not enough fields specified.

 

 

E3H

PCCC Description: Illegal Address format, too many fields specified.

 

 

E4H

PCCC Description: Illegal Address, symbol not found.

 

 

E5H

PCCC Description: Illegal Address Format, symbol is 0 or greater than the maximum number of characters support by this

 

device.

 

 

Publication 1761-UM006A-EN-P - February 2001

Image 82
Contents MicroLogix Ethernet Interface ENI Cat. No -NET-ENIAllen-Bradley is a trademark of Rockwell Automation Table of Contents Chapter Preface Who Should Use this ManualRelated Documentation For Read this DocumentTechnical Product Assistance Local Product SupportYour Questions or Comments on this Manual Preface P-4 Publication 1761-UM006A-EN-P January Product Overview Ethernet Connection Non-Ethernet DevicesProduct Drawing Hardware FeaturesLED Indicators Description Function ColorRS-232 Settings Default Other Options Default SettingsDF1 Settings Default Other Options Messaging Operating ModesDevice Compatibility MailEthernet Networks Using a Web Browser with the ENIBasic Ethernet Topology 6Product Overview Publication 1761-UM006A-EN-P February EMC Directive Low Voltage DirectiveSafety Considerations Mounting DIN Rail MountingPanel Mounting RemovalExternal Power Supply Wiring ENI Port IdentificationEthernet Connections Ethernet 8-Pin 10Base-T Connector PortPin Pin Name Ethernet Cables Maintain ENI ConnectionsRS-232 Cables RS-232 ConnectorRS-232 Connector Pin Assignments ENI Connected to Catalog Number Use CableOutgoing messages Operation OverviewNumber of Connections Dedicated to Incoming messagesRSLinx on Ethernet PC Connected to Ethernet ENI Functional OverviewOperation 4Operation RSLogix 6Operation ENI Configuration Node 248 to ENI Configuration UtilityCOM Port Settings RS-232 Baud Rate and TCP/IP ParametersMail Settings Save to ENI RAM or ENI ROMReset Message RoutingController Messaging Configuring ENI Data Parameters Target Device Parameters Configuring ENI String Parameters Configuring the ENI E-Mail From StringAlways set this to Node Function Data Type Number Options Default Elements Node 249 From String Node 248 Save/Reset FunctionSave/Reset ValueNode 250 TCP/IP Configuration TCP/IP Configuration Parameters Function Data Type LengthSubnet Mask is in auto-detect Subnet Mask Auto-Detect OperationSubnet Mask is set to Security Mask Behavior Example Condition Node 251 E-Mail Server Node 252 Bootp ConfigurationNode 253 Baud Rate ENI Baud Rate Options Configuration Value Integer Node 254 Ethernet Hardware AddressPeer-to-Peer Messaging Node Node100 Configuration Node TCP/IP addressMessage Routing ENI receives read or Node Node101102 Route 2 Address 100 Route 0 Address101 Route 1 Address 103 Route 3 AddressFunction ENI Node DF1 Message Routing148 Use any command supported by your controller Data Table Address Use any valid file Size in ElementsPage Mail Messages Node 50 to OverviewConfiguring E-Mail Smtp E-Mail AddressDestination Addresses Message TextMessage Fields to, from, subject Mail Mail Address Description Message ConfigurationNode Sending an E-Mail Message Mail messages System Diagram Example NetworkPurpose Scope RSLOGIX500131.200.50.95 Example Network IP Addresses Device131.200.50.96 Computer’s Ethernet card Configuring 1761-NET-ENI #1 Throttling Message InstructionsENI #1 Configuration ENI IP Addr Screen Configuring 1761-NET-ENI #2 Message Routing Nodes FunctionENI #2 Configuration RSLogix 5000 Ladder Program ENI #2 Configuration Message Instructions Parameters ENI #2 Configuration Rung Descriptions FunctionMessage Message Function Publication 1761-UM006A-EN-P February ENI #2 Configuration Message ConfigurationTab 10 L20 Controller’s Tags 11 File Mapping in RSLogix Configure Rslinx 1769-L2013 Modify DF1 Parameters Using RSLInx 14 SLC 5/05 Controller Ladder Program 15 SLC 5/05 Rung 0 MSG General Tab 17 SLC 5/05 Rung 1 MSG General Tab 19 ControlLogix 5550 Controller Ladder Program 20 ControlLogix 5550 Rung 0 Message Configuration Tab 22 ControlLogix 5550 Rung 1 Message Configuration Tab Configuring an Ethernet Driver in Rslinx 25 Configure Ethernet Driver Using RSLinx On solid for 2 seconds Power-Up SequenceFlashes for 4 seconds Description Color State Indicates Error Codes Generated by the ENI Message Instruction Error CodesError Code Description of Error Condition Connection not completed before user-specified timeout Pccc Description Remote station problem due to downloadPccc Description Cannot execute command due to active IPBs Reply not received before user-specified timeoutPccc Description Data conversion error Pccc Description Command cannot be executedPccc Description No access Pccc Description Overflow histogram overflow6Troubleshooting Publication 1761-UM006A-EN-P February Description ENI Specification Physical SpecificationsMicroLogix Web Site Mounting Dimensions DimensionsProduct Dimensions Gateway Optional1 TCP/IP Parameters Function FormatOn the subnet mask ZeroUsing Bootp Install the Bootp ServerEdit the Bootp Configuration File Device Name IP Address Hardware Address Ethernet TCP/IPParameters if necessary Windows From See This platform ExecutableDOS-based Windows Program ManagerRunning the Windows-Based Utility Running the DOS-Based UtilityParameter Description Glossary Node Pccc Programmable Controller Communications Commands RS-232 UTP Unshielded Twisted Pair Allocation of Ethernet connections 3-1Ethernet switch IndexMTA TCP Index Publication 1761-UM006A-EN-P February Page Publication 1761-UM006A-EN-P February