HP
MicroLogix 1761-NET-ENI
manual
ControlLogix 5550 Rung 0 Message Configuration Tab
Specification
Install
System Diagram
Default Settings
LED Indicators
External Power Supply Wiring
Dimension
ENI Configuration Node 248 to
Reset
Pccc Description No access
Page 75
Connecting
1769-L20
CompactLogix Controllers on Ethernet
7-19
Figure 7.20 ControlLogix 5550 Rung 0 Message Configuration Tab
Figure 7.21 ControlLogix 5550 Rung 0 Message Communication Tab
Publication
1761-UM006A-EN-P
- February 2001
Page 74
Page 76
Image 75
Page 74
Page 76
Contents
Cat. No -NET-ENI
MicroLogix Ethernet Interface ENI
Allen-Bradley is a trademark of Rockwell Automation
Table of Contents
Chapter
Who Should Use this Manual
Preface
For Read this Document
Related Documentation
Local Product Support
Technical Product Assistance
Your Questions or Comments on this Manual
Preface P-4 Publication 1761-UM006A-EN-P January
Ethernet Connection Non-Ethernet Devices
Product Overview
Description Function Color
Hardware Features
LED Indicators
Product Drawing
Default Settings
RS-232 Settings Default Other Options
DF1 Settings Default Other Options
Mail
Operating Modes
Device Compatibility
Messaging
Using a Web Browser with the ENI
Ethernet Networks
Basic Ethernet Topology
6Product Overview Publication 1761-UM006A-EN-P February
Low Voltage Directive
EMC Directive
Safety Considerations
DIN Rail Mounting
Mounting
Removal
Panel Mounting
ENI Port Identification
External Power Supply Wiring
Ethernet 8-Pin 10Base-T Connector Port
Ethernet Connections
Pin Pin Name
Maintain ENI Connections
Ethernet Cables
ENI Connected to Catalog Number Use Cable
RS-232 Connector
RS-232 Connector Pin Assignments
RS-232 Cables
Incoming messages
Operation Overview
Number of Connections Dedicated to
Outgoing messages
ENI Functional Overview
RSLinx on Ethernet PC Connected to Ethernet
Operation
4Operation
RSLogix
6Operation
ENI Configuration Utility
ENI Configuration Node 248 to
RS-232 Baud Rate and TCP/IP Parameters
COM Port Settings
Save to ENI RAM or ENI ROM
Mail Settings
Message Routing
Reset
Controller Messaging
Configuring ENI Data Parameters
Target Device Parameters
Configuring the ENI E-Mail From String
Configuring ENI String Parameters
Always set this to
Node Function Data Type Number Options Default Elements
Value
Node 248 Save/Reset Function
Save/Reset
Node 249 From String
TCP/IP Configuration Parameters Function Data Type Length
Node 250 TCP/IP Configuration
Subnet Mask Auto-Detect Operation
Subnet Mask is in auto-detect
Subnet Mask is set to
Security Mask Behavior Example Condition
Node 252 Bootp Configuration
Node 251 E-Mail Server
Node 253 Baud Rate
Node 254 Ethernet Hardware Address
ENI Baud Rate Options Configuration Value Integer
Peer-to-Peer Messaging
Node Node101
Configuration Node TCP/IP address
Message Routing ENI receives read or
Node Node100
103 Route 3 Address
100 Route 0 Address
101 Route 1 Address
102 Route 2 Address
DF1 Message Routing
Function ENI Node
148
Data Table Address Use any valid file Size in Elements
Use any command supported by your controller
Page
Overview
Mail Messages Node 50 to
Smtp E-Mail Address
Configuring E-Mail
Message Text
Destination Addresses
Mail Mail Address Description Message Configuration
Message Fields to, from, subject
Node
Sending an E-Mail Message
Mail messages
Example Network
System Diagram
RSLOGIX500
Purpose Scope
Example Network IP Addresses Device
131.200.50.95
131.200.50.96 Computer’s Ethernet card
Throttling Message Instructions
Configuring 1761-NET-ENI #1
ENI #1 Configuration ENI IP Addr Screen
Message Routing Nodes Function
Configuring 1761-NET-ENI #2
ENI #2 Configuration RSLogix 5000 Ladder Program
ENI #2 Configuration Rung Descriptions Function
ENI #2 Configuration Message Instructions Parameters
Message Message Function
Publication 1761-UM006A-EN-P February
ENI #2 Configuration Message ConfigurationTab
10 L20 Controller’s Tags
11 File Mapping in RSLogix
1769-L20
Configure Rslinx
13 Modify DF1 Parameters Using RSLInx
14 SLC 5/05 Controller Ladder Program
15 SLC 5/05 Rung 0 MSG General Tab
17 SLC 5/05 Rung 1 MSG General Tab
19 ControlLogix 5550 Controller Ladder Program
20 ControlLogix 5550 Rung 0 Message Configuration Tab
22 ControlLogix 5550 Rung 1 Message Configuration Tab
Configuring an Ethernet Driver in Rslinx
25 Configure Ethernet Driver Using RSLinx
Power-Up Sequence
On solid for 2 seconds
Flashes for 4 seconds
Description Color State Indicates
Message Instruction Error Codes
Error Codes Generated by the ENI
Error Code Description of Error Condition
Reply not received before user-specified timeout
Pccc Description Remote station problem due to download
Pccc Description Cannot execute command due to active IPBs
Connection not completed before user-specified timeout
Pccc Description Overflow histogram overflow
Pccc Description Command cannot be executed
Pccc Description No access
Pccc Description Data conversion error
6Troubleshooting Publication 1761-UM006A-EN-P February
Physical Specifications
Description ENI Specification
MicroLogix Web Site
Dimensions
Mounting Dimensions
Product Dimensions
Zero
TCP/IP Parameters Function Format
On the subnet mask
Gateway Optional1
Install the Bootp Server
Using Bootp
Edit the Bootp Configuration File
Ethernet TCP/IP
Device Name IP Address Hardware Address
Windows Program Manager
From See This platform Executable
DOS-based
Parameters if necessary Windows
Running the DOS-Based Utility
Running the Windows-Based Utility
Parameter Description
Glossary
Node
Pccc Programmable Controller Communications Commands RS-232
UTP Unshielded Twisted Pair
Index
Allocation of Ethernet connections 3-1Ethernet switch
MTA
TCP
Index Publication 1761-UM006A-EN-P February
Page
Publication 1761-UM006A-EN-P February
Related pages
All Configuration page
What are the performance tests for the N3304A model?
Learn more
(#)
Top
Page
Image
Contents