HP A4800A manual MPE/iX

Page 46

SCSI Sense Codes

 

HP 9000

The following example shows a typical SCSI error message:

[+6708 72410001 002a9858 0:7] scsi disk: CHECK CONDITION on disk 0:6:5:0

Read of logical block 509856, count 128

 

disk sd45a, block 254920, 65536 bytes

 

Valid = 1, Error

code = 0x70

 

Segment number =

0x00, Filemark = 0, EOM = 0, ILI = 0

Sense key = 0x1,

"RECOVERED ERROR"

 

Information = 0x00 0x07 0xc7 0xe4

 

[+6709 72410001 002a9a10 0:7] scsi disk:

Additional sense length = 0x0a

Command-specific

information = 0x00 0x00 0x00 0x00

Additional sense

= 0x18, Qualifier = 0x01

Field replaceable unit code = 0xea

 

SKSV = 1, C/D = 0, BPV = 0, Bit pointer = 0

Field pointer = 0x0003

 

 

The status (CHECK CONDITION) and sense key (RECOVERED

 

ERROR)—shown in bold in the example above—are interpreted for you

 

in the error message text. Each Additional sense and its corresponding

 

Qualifier code—shown in bold in the example above—require

 

interpretation on your part. Use the two codes together to determine the

 

meaning. In the example above, the Additional sense (0x18) and

 

Qualifier (0x01) codes together mean “recovered data with error

 

correction and retries applied.” You can look up the various codes and

 

keys in the tables on the next pages.

MPE/iX

Use the CSTM tool to look at hardware error information. Information

 

about CSTM can be found in the article “TERMDSM: User Interface

 

Change undre System Diagnostics” in the “Communicator 3000 MPE/iX

 

Release 6.5”. http://docs.hp.com/mpeix/pdf/30216-90291.pdf

46

Appendix A

Image 46
Contents HP A4800A PCI FWD Scsi Host Bus Adapter Manufacturing Part Number A3725-96031 E0201Legal Notices Page Page HP A4800A Adapter Overview HP A4800A Adapter Overview About the A4800A Adapter Below is a drawing of the A4800A adapter A4800A PCI Ultra HVD Scsi Host Bus AdapterFeatures Supported HP 9000 Servers Cable Specifications Cables for Connecting External Scsi Devices to the A4800AA5068A Scsi Cable Kit Description Part Number Adapter in V-Class Systems Description Product Option Number Installing the A4800A Adapter Installing the A4800A Adapter Preparing for Installation Connecting to External Scsi Devices Handling the A4800A Adapter Looking at Adapter Installation Important Terms and ConceptsImportant Terms Meaning OlarPlanning and Preparation Card Compatibility OLA/R Restrictions for the A4800A A4800-60001 Default Scsi Attribute ValuesAttribute Default Value StepLooking at Adapter Installation Reassemble the server Connecting Scsi Peripheral Devices Scsi12.5 Fast Scsi Fast Wide Connecting Scsi Peripheral Devices Terminating the A4800A Adapter Setting Scsi IDs Record of Scsi IDs Scsi DeviceVerifying Installation HP e3000 Troubleshooting Troubleshooting General Procedure Checking Scsi Bus Compatibility ClearpimScsi Command Displaying Transfer RatesSetting Transfer Rates Displaying Scsi IDs Setting Scsi IDs Using Support Tools Manager STM Contacting Your Hewlett-Packard Representative Contacting Your Hewlett-Packard Representative Contacting Your Hewlett-Packard Representative Chapter Scsi Sense Codes MPE/iX Table A-1 Scsi Status Codes Status Meaning CodeTable A-2 Scsi Sense Keys Sense Meaning KeyTable A-3 Scsi Additional Sense Code/Qualifier Code Pairs Addition Qualifier Meaning Al Sense CodeLogical unit not ready, cause not ID crc or ecc error Recorded entity not found Recovered data with error correction Applied Logical block address out of range Commands cleared by another initiator Sequential positioning error Target operation conditions have Changed Write append error Log exception 0x69 0x00 Regulatory Information Regulatory Statements FCC Statement For U.S.A. OnlyVcci Statement Japan Declaration of Conformity