HP A4800A manual Recovered data with error correction Applied

Page 53

 

 

 

SCSI Sense Codes

Table A-3

SCSI Additional Sense Code/Qualifier Code Pairs (Continued)

 

 

 

 

 

 

SCSI

SCSI

 

 

 

Addition

 

 

 

Qualifier

Meaning

 

 

al Sense

 

 

Code

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

0x18

0x00

Recovered data with error correction

 

 

 

 

applied

 

 

 

 

 

 

 

 

0x01

Recovered data with error correction and

 

 

 

 

retries applied

 

 

 

 

 

 

 

 

0x02

Recovered data—data auto-reallocated

 

 

 

 

 

 

 

 

0x03

Recovered data with circ

 

 

 

 

 

 

 

 

0x04

Recovered data with lec

 

 

 

 

 

 

 

 

0x05

Recovered data—recommend

 

 

 

 

reassignment

 

 

 

 

 

 

 

 

0x06

Recovered data—recommend rewrite

 

 

 

 

 

 

 

0x19

0x00

Defect list error

 

 

 

 

 

 

 

 

0x01

Defect list not available

 

 

 

 

 

 

 

 

0x02

Defect list error in primary list

 

 

 

 

 

 

 

 

0x03

Defect list error in grown list

 

 

 

 

 

 

 

0x1a

0x00

Parameter list length error

 

 

 

 

 

 

 

0x1b

0x00

Synchronous data transfer error

 

 

 

 

 

 

 

0x1c

0x00

Defect list not found

 

 

 

 

 

 

 

 

0x01

Primary defect list not found

 

 

 

 

 

 

 

 

0x02

Grown defect list not found

 

 

 

 

 

 

 

0x1d

0x00

Miscompare during verify operation

 

 

 

 

 

 

 

0x1e

0x00

Recovered ID with ecc

 

 

 

 

 

 

 

0x20

0x00

Invalid command operation code

 

 

 

 

 

 

Appendix A

53

Image 53
Contents Manufacturing Part Number A3725-96031 E0201 HP A4800A PCI FWD Scsi Host Bus AdapterLegal Notices Page Page HP A4800A Adapter Overview HP A4800A Adapter Overview About the A4800A Adapter A4800A PCI Ultra HVD Scsi Host Bus Adapter Below is a drawing of the A4800A adapterFeatures Supported HP 9000 Servers A5068A Scsi Cable Kit Description Part Number Cables for Connecting External Scsi Devices to the A4800ACable Specifications Adapter in V-Class Systems Description Product Option Number Installing the A4800A Adapter Installing the A4800A Adapter Preparing for Installation Connecting to External Scsi Devices Handling the A4800A Adapter Important Terms and Concepts Looking at Adapter InstallationOlar Important Terms MeaningPlanning and Preparation Card Compatibility Attribute Default Value A4800-60001 Default Scsi Attribute ValuesOLA/R Restrictions for the A4800A StepLooking at Adapter Installation Reassemble the server Scsi Connecting Scsi Peripheral Devices12.5 Fast Scsi Fast Wide Connecting Scsi Peripheral Devices Terminating the A4800A Adapter Setting Scsi IDs Scsi Device Record of Scsi IDsVerifying Installation HP e3000 Troubleshooting Troubleshooting General Procedure Clearpim Checking Scsi Bus CompatibilityDisplaying Transfer Rates Scsi CommandSetting Transfer Rates Displaying Scsi IDs Setting Scsi IDs Using Support Tools Manager STM Contacting Your Hewlett-Packard Representative Contacting Your Hewlett-Packard Representative Contacting Your Hewlett-Packard Representative Chapter Scsi Sense Codes MPE/iX Status Meaning Code Table A-1 Scsi Status CodesSense Meaning Key Table A-2 Scsi Sense KeysAddition Qualifier Meaning Al Sense Code Table A-3 Scsi Additional Sense Code/Qualifier Code Pairs Logical unit not ready, cause not ID crc or ecc error Recorded entity not found Recovered data with error correction Applied Logical block address out of range Commands cleared by another initiator Sequential positioning error Target operation conditions have Changed Write append error Log exception 0x69 0x00 Regulatory Information FCC Statement For U.S.A. Only Regulatory StatementsVcci Statement Japan Declaration of Conformity