SCSI Sense Codes

Table A-3

SCSI Additional Sense Code/Qualifier Code Pairs (Continued)

 

 

 

 

 

 

SCSI

SCSI

 

 

 

Addition

 

 

 

Qualifier

Meaning

 

 

al Sense

 

 

Code

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

0x10

0x00

ID crc or ecc error

 

 

 

 

 

 

 

0x11

0x00

Unrecovered read error

 

 

 

 

 

 

 

 

0x01

Read retries exhausted

 

 

 

 

 

 

 

 

0x02

Error too long to correct

 

 

 

 

 

 

 

 

0x03

Multiple read errors

 

 

 

 

 

 

 

 

0x04

Unrecovered read error—auto reallocate

 

 

 

 

failed

 

 

 

 

 

 

 

 

0x05

l-ec uncorrectable error

 

 

 

 

 

 

 

 

0x06

circ unrecovered error

 

 

 

 

 

 

 

 

0x07

Data resynchronization error

 

 

 

 

 

 

 

 

0x08

Incomplete block read

 

 

 

 

 

 

 

 

0x09

No gap found

 

 

 

 

 

 

 

 

0x0a

Miscorrected error

 

 

 

 

 

 

 

 

0x0b

Unrecovered read error—recommend

 

 

 

 

reassignment

 

 

 

 

 

 

 

 

0x0c

Unrecovered read error—recommend

 

 

 

 

rewrite the data

 

 

 

 

 

 

 

0x12

0x00

Address mark not found for ID field

 

 

 

 

 

 

 

0x13

0x00

Address mark not found for data field

 

 

 

 

 

 

Appendix A

51

Image 51
Contents Manufacturing Part Number A3725-96031 E0201 HP A4800A PCI FWD Scsi Host Bus AdapterLegal Notices Page Page HP A4800A Adapter Overview HP A4800A Adapter Overview About the A4800A Adapter A4800A PCI Ultra HVD Scsi Host Bus Adapter Below is a drawing of the A4800A adapterFeatures Supported HP 9000 Servers Cables for Connecting External Scsi Devices to the A4800A Cable SpecificationsA5068A Scsi Cable Kit Description Part Number Adapter in V-Class Systems Description Product Option Number Installing the A4800A Adapter Installing the A4800A Adapter Preparing for Installation Connecting to External Scsi Devices Handling the A4800A Adapter Important Terms and Concepts Looking at Adapter InstallationOlar Important Terms MeaningPlanning and Preparation Card Compatibility Step A4800-60001 Default Scsi Attribute ValuesAttribute Default Value OLA/R Restrictions for the A4800ALooking at Adapter Installation Reassemble the server Scsi Connecting Scsi Peripheral Devices12.5 Fast Scsi Fast Wide Connecting Scsi Peripheral Devices Terminating the A4800A Adapter Setting Scsi IDs Scsi Device Record of Scsi IDsVerifying Installation HP e3000 Troubleshooting Troubleshooting General Procedure Clearpim Checking Scsi Bus CompatibilityDisplaying Transfer Rates Scsi CommandSetting Transfer Rates Displaying Scsi IDs Setting Scsi IDs Using Support Tools Manager STM Contacting Your Hewlett-Packard Representative Contacting Your Hewlett-Packard Representative Contacting Your Hewlett-Packard Representative Chapter Scsi Sense Codes MPE/iX Status Meaning Code Table A-1 Scsi Status Codes Sense Meaning Key Table A-2 Scsi Sense KeysAddition Qualifier Meaning Al Sense Code Table A-3 Scsi Additional Sense Code/Qualifier Code PairsLogical unit not ready, cause not ID crc or ecc error Recorded entity not found Recovered data with error correction Applied Logical block address out of range Commands cleared by another initiator Sequential positioning error Target operation conditions have Changed Write append error Log exception 0x69 0x00 Regulatory Information FCC Statement For U.S.A. Only Regulatory StatementsVcci Statement Japan Declaration of Conformity