Visual Basic
W_9112_GetOverrunStatus(ByVal card_number As Long, overrunCount As Long) As Long
C/C++ ( DOS)
int _9112_GetOverrunStatus (int card_number, int *overrunCount )
uArgument
card_number : the card number of
overrunCount: number of overrun counts.
uReturn Code
ERR_NoError, ERR_BoardNoInit
uExample
See Demo Program 'AD_DEMO5.C'
5.21 _9112_ContDmaStop
uDescription
This function is used to stop the continuous DMA data transferring.
uSyntax
Visual C++
int W_9112_ContDmaStop (int card_number)
Visual Basic
W_9112_ContDmaStop (ByVal card_number As Long) As Long
C/C++ ( DOS)
int _9112_ContDmaStop (int card_number)
uArgument :
card_number : the card number of
uReturn Code :
ERR_NoError, ERR_BoardNoInit
uExample :
See Demo Program 'AD_DEMO5.C'