Turn up thermostat. | No | Is there power (230V) | Yes | |
to the control panel? | ||||
Does the fan turn on? | ||||
|
|
| ||
|
| No |
|
Check thermostat
and replace if
necessary.
Check clock program.
Reset as required.
No
Is the clock set to on?
Fan motor may have to
be replaced.
| Is there power output |
| Refer to control panel |
|
|
Yes | No | IOS manual for |
|
| |
to the fan? |
|
| |||
|
| troubleshooting. |
|
| |
| Yes |
|
|
| |
|
|
|
|
| |
| Disconnect power to the |
| Motor may have have tripped |
| Is the motor connected |
| Yes | overload switch. Wait | No | properly? Refer to the wiring | |
| motor. Does the | ||||
| 10 - 15 minutes for | diagrams on the motor and | |||
| motor turn freely? |
|
| ||
|
| automatic reset. |
| in the installation manual. | |
| No |
|
| ||
|
|
|
|
| |
No | Is there an obstruction to | Yes | Remove obstruction. |
|
|
the pump impeller? |
|
| |||
|
|
|
|
|
16.2 Troubleshooting Flow Chart (Multiburner)
Yes |
|
|
| |
After 20 second |
| Unplug burner and check |
| |
No | electrode and ignition wire. | No | ||
Is there spark at the igniter? | ||||
|
| Are they damaged? |
| |
|
| Yes |
| |
|
| Replace electrode and |
| |
|
| ignition wire as needed. |
|
Is the igniter gap |
| Is the flue pipe or |
| |
Yes | the inlet of the | Yes | ||
set at 3 mm? | ||||
| burner obstructed? |
| ||
|
|
| ||
No |
| No |
| |
Carefully reset gap |
| Are the hoses to the pressure | No | |
to 3 mm. |
| switch secure and leak free? |
| |
|
| Yes |
|
Remove obstruction.
Repair, replace or
tighten hoses as necessary.
67 of 75
Replace automatic
control unit.
Remove Black and Yellow No leads from the pressure switch;
place a jumper between leads.
Is there a spark?
Yes
Replace pressure switch.
SECTION 16: TROUBLESHOOTING