Roberts Gorden BH30DL, BH35UT/EF Troubleshooting Flow Chart Linear, Double Linear and U-Tube

Page 72

66 of 74

Yes

Does the burner light?

No

Yes

 

Does the burner

No

stay on?

 

Yes

 

Does the burner turn off

No

when the call for heat ends?

Yes

 

TROUBLESHOOT ENDS.

If problems persist, contact

Roberts-Gordon at

Tel: +44 (0)121 506 7700 or

Fax: +44 (0)121 506 7701 or

online at www.rg-inc.com

Were the gas lines

No

purged of air correctly?

 

Yes

 

Is there sufficient inlet gas pressure (See Specification Yes

Section) during ignition?

No

Check gas line stop cock. Check gas supply at meter.

Contact gas company.

Is the continuity of the

Yes

earth wire established?

 

No

 

Reestablish continuity.

 

Check the thermostat and check the continuity of the ground wire.

Purge Lines.

Measure voltage on valve terminals. Is there 230 V during ignition time?

No

Are the wires connecting the automatic control unit OK?

Yes

Replace automatic

control unit.

Are the Live and Neutral

reversed?

Yes

Reverse polarity.

Check for the proper jet and air plate inside the burner.

Yes

Is the gas outlet pressure

in accordance with

specification section No of this manual?

Yes

Yes

Is there gas outlet pressure

No

available during the

 

ignition period?

 

No

Replace/Correct wires.

 

No

Is the wiring at the

Yes

module properly

 

connected?

 

 

No

 

 

Re-establish connections.

 

Adjust the governor

pressure.

Replace solenoid

coil.

Ignition module may have failed. Replace module.

Yes

Is the insulation on the electrode/sensor leads OK?

No

Replace/Correct

Wires.

Troubleshooting Flow Chart (Linear, Double Linear and U-Tube)

BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL

Image 72
Contents If you smell gas OwnerPage Table of Contents Roberts-Gordon LLCPage Table of Figures Linear & Double Linear, One Side ReflectorPage Product Approval Heater Safety Manpower RequirementsSafety Labels and Their Placement Top Panel Label Placement Installer Responsibility Low Level User InstructionsNational Standards and Applicable Codes Clearances to Combustibles BH40ST/EF BH45ST/EFBH15ST BH30DL BH20ST BH40DLBH55ST BH35ST/EF BH70DL/EFClearance Data -U Tube BH15UTBH20UT 200 1370 1500 560 200 1530 1650 560250 1630 1860 560 250 1780 1960 560Major Component Descriptions General Suspension Details Typical Suspension Details Linear & Double Linear Heater Installation Linear Standard Parts ListDescription Clips Weld SpotBurner Tube BH15ST f BH20ST fBH35ST/EF f BH45ST/EFBH50ST/EF f BH55ST fDouble Linear Standard Parts List Clips Assembly Coupling Burner Tube Reflector Support Tube and ReflectorRepeated SideReflector Overlap approx Burner Tube Installation Coupling and Tube AssemblyOpen Closed1 Coupling and Tube Assembly 2 Coupling and Tube AssemblyTighten slide bar as shown below Tube Clamp Package Installation 02750303 Option B Option aFan Tube Weld Spot Coupling Tee Fan TubeTube Heater Installation Tube Standard Parts List94320812 Tube Assembly Overview 200 mmBH35UT/EF g Reflector Overlap 1780 mm690 mm U-Tube Hanger Placement Burner Tube and Fan Tube Installation1 Tube Clamp Package Installation U-Tube Support Bracket Assembly InstallationBolt Nut Torque 13.56 Nm Lock Washer Tube ClampOrient coupling so that Impact block is Tube Installation U-Tube InstallationTube Support Bracket Assembly Coupling Reflector 02750303 Reflector Support Strap 03050000 Screw #8 x 3/4 3.9 x 19mm Multiburner Configuration & Installation Fan Tube Weld Spot Install Fully open positionDamper Flange Typical Fan Arrangement Mm Hanger Cross Mm Manifold Damper Typical CrossMm Manifold Max 1000 3000 mm Tee ID/ID Sleeve Mm Hanger ReducerBurner & FAN Installation Burner InstallationFan Assembly Double Linear Fan Installation Tighten securely until tubeCannot be removed Tee Tighten securely until tube Cannot be removed1 Double Linear Fan Installation Use 1 x ¾ reducerNot supplied Non-Return ValveCondensate Drain Assembly Optional Heater Accessories 2 Side Reflector Installation Per reflector Use additional supports High air movementShe et Met al Screw Tube Cover Installation StepUse six #8 sheet metal screws to attach the joint piece Decorative Grille Installation .3.1 Grille Installation 2 Frame Shield Installation2 Grille End Cap Installation 3 Grille InstallationSports Hall Guard Installation 2 Fastener Installation1 Grille Installation 3 Mesh Guard ConnectionUndershield Installation 10.6.1 Hanger Installation Undershield InstallationAdjust Undershield Height Hardware Installation Wall MountingLinear Venting Outside Combustion Air Supply Air Supply RequirementsEnd of Tube Fan Tube Fresh Air Intake Spigot Common DuctGAS Piping Connector 545 mm Minimum Burner Shut-Off Valve Supplied by Roberts-Gordon 1000 mm LongGas Supply Pipe Wiring Typical External Wiring Diagram Linear or U-TubeTypical External Wiring Diagram Double Linear Option Typical External Wiring Diagram Multiburner Internal Wiring Diagram Operation and service OperationTubing may still be hot Heater Lockout Indication OptionalHeater Lockout Indicator by Connector Heater Lockout Indicator by Volt Free ConnectorTesting Commissioning MultiburnerECA Approved Systems Multiburner only Servicing Instructions Pressure Switch Automatic Flame Control UnitNeons Vehicles and Other ObjectsTubes Gas LineBurner Observation WindowTroubleshooting Troubleshooting Flow Chart Linear, Double Linear U-TubeTroubleshooting Flow Chart Linear, Double Linear and U-Tube Troubleshoot EndsTroubleshooting Flow Chart Multiburner Troubleshooting Flow Chart Multiburner Re-establish continuity Purge LinesManifold Gas Pressure Setting Governor orifice pressureWhile burner is running. See Replacement Parts Item Description Specifications Linear Heater Double Linear HeaterTube Heater Burner Specifications StandardBH15 BH20 BH25 BH30 BH35 BH40 BH45 BH50 BH55 Burner Airplate ID Number Jet Numbers #30 #19 Natural G20EF Burner Specifications BH25/EF BH30/EF BH35/EF BH40/EF BH45/EF BH50/EFPage Page F r a r e d H e a t i n g