Magnum 3000 Stackable Hubs | Installation and User Guide (07/06) |
B4.1 UL Requirements
1.Minimum 14 AWG cable for connection to a Centralized DC power source.
2.Fastening torque of the lugs on the terminal block: 9 inch pound max.
3.Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block.
4.Disconnect Device Statement - Statement indicating that a readily accessible disconnect device shall be incorporated in the building installation wiring. (Instruction).
5.This product shall be provided with a Listed fuse or circuit breaker, rated 5 A, in the supply circuit when connected to a 48 V centralized dc source.
B5.0 OPERATION
Operation of the Magnum 3000s with the optional
B6.0 ORDERING INFORMATION
To order the optional
Similarly, to order the optional 24VDC or 125VDC industrial specific power supply factory installed, add a suffix of
B7.0 | TROUBLESHOOTING | Please refer to Section 6.0 |
APPENDIX C : Internal DC Dual-Source Power Option
C1.0 SPECIFICATIONS - FOR MAGNUM 3000S HUBS
Power Supply (Internal,
DC Power Connector: First Source: “A+”,
GND: | Terminal for “earth” or ground wire connection to the hub chassis |
Input: | Two separate sources, each at 36 - 70 VDC |
Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.
Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..
Power Supply (Internal, 24VDC
DC Power Connector: First Source: “A+”,
GND: | Terminal for “earth” or ground wire connection to the hub chassis |
Input: | Two separate sources, each at 20 - 36 VDC |
Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.
Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..
Power Supply (Internal, 125VDC
DC Power Connector: First Source: “A+”,
www . GarrettCom . com
49