Magnum 3000 Stackable HubsInstallation and User Guide (07/06)

The ETSI (European Telephone Standard) brackets are similar to the 19” brackets but use

metric dimensions.

The

Magnum 3000

optional 23”

Stackable Hub

 

GARRETT

brackets and the

 

ETSI brackets

Stackable Hub

come as a pair in a

Magnum 3000

GARRETT

package along with

 

the necessary

GARRETT

 

Magnum 3000

 

Stackable Hub

screws for

 

attaching the

Stackable Hub

brackets to the

Magnum 3000

GARRETT

sides of the

 

Magnum Hub unit.

 

Fig 3.1 Multiple Magnum 3000 units rack-mounted in a 23” Rack-mount frame

The following instructions need to be follow up before installations-

A)Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

B)Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

C)Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

D)Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E)Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."