2.3Magnum 3024 Hub - 24 RJ-45 Ports, One PM bonus port slot

The Magnum 3024 Hub provides 24 RJ-45 ports on the front of the unit plus a

Bonus Port slot on the rear which may be configured with any Magnum Port Module (PM). User-segment wiring connections are made on the front of the unit, and status- indicator LEDs are located immediately above each of the 24 ports.

Two LEDs (RX & LINK)

for each RJ-45 10BASE-T port.

Magnum 3000

Stackable Hub

Steady On LINK LED = Port is Operational Flashing LINK LED = Port is Partitioned Flashing RX LED = Port Activity

GARRETT

Twenty-four RJ-45 10BASE-T Ports

Figure 2.3a, Magnum 3024 Hub, Front View

The shielded RJ-45 port connectors on the front are electrically connected to the metal case of the unit, and are helpful in reducing electromagnetic noise radiation from the unit. (Note that the 10BASE-T wiring cable to the user may be unshielded or shielded, Category 3 or 4 or 5. The choice of wiring type is left to the installer based on preferences, standard practices and local or national wiring codes.)

AC Power

Bonus Port Slot- Configurable via P1: Remote Terminal

Inter-Repeater Bus (IRB)

Connector

Port Module (PM)

RS-232 Port

P3 - Interface to unit above.

 

 

(Embedded Agent Only)

P4 - Interface to unit below.

.. .. .. .. .

 

P3

1

8

 

P4

Eight (8) position dip switch.

1 - 6 = Address of Repeater Unit (1-20)

7 = Not Used - Previously used to allow PC based SNMP Agent 8 = Not Used

NOTE: P1 also used to setup IP address and configuration files.

Figure 2.3b, Magnum 3024 (and 3012), Rear View

2.3.1Stacking Magnum 3000s

The rear of the Magnum 3000 Stackable Hubs have an Inter-Repeater Bus

(IRB) connector on the right side. The IRB interconnects stacked units with a shielded ribbon cable, enabling all stacked Magnum 3000 units to operate as a single repeater.

There are two 34-pin IRB connectors on each unit: the bottom IRB connector which is used to daisy chain the IRB to the stacked Magnum 3000 unit below (unused on bottom unit in a Magnum 3000 stack); and the top IRB connector which is used to daisy chain the IRB to the stacked Magnum 3000 unit above (unused on top unit in a Magnum 3000 stack). The IRB connectors for an non-stacked unit are unused.