Magnum 3000 Stackable HubsInstallation and User Guide (07/06)

APPENDIX B : Internal DC Power Supply Option

B1.0 SPECIFICATIONS - FOR MAGNUM 3000S

Power Supply (Internal -48VDC Option)

DC Power Connector: 3 terminals: -“, “GND”, “+”

Input Voltage: 36 - 70 VDC

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max.

Power Supply (Internal 24 VDC Option) Industrial Application DC Power Connector: 3 terminals: -“, “GND”, “+” Input Voltage: 20 - 36 VDC

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..

Power Supply (Internal 125 VDC Option) Industrial Application DC Power Connector: 3 terminals: -“, “GND”, “+” Input Voltage: 120 - 160 VDC

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max.

With the exception of the power supply, all specifications and functions of Magnum 3000s-48VDC, 24VDC and 125VDC models are identical to those listed in the main manual.

B2.0 -48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF OPERATION

The -48VDC, 24VDC & 125VDC power options are designed using diodes inside on each DC power input line behind the two external power connection terminals,

so that the power from an external source can only flow into the hub. This allows the 3000s to operate only whenever DC power is correctly applied to the two inputs. It protects

A+

A-

GND

POWER SWITCH

HUB

 

 

SUPPLY

 

+

 

- FUSE

 

CHASSIS

 

GND

the 3000s from incorrect DC input connections. An incorrect polarity connection, for example, will neither affect the 3000s, its internal power supply, nor will it blow the fuse in the internal power supply.

The manual power “On-Off” Switch (optional) is used for powering the unit on and off when it is placed into or taken out of service.

B3.0 APPLICATIONS FOR DC POWERED HUBS

Magnum 3000’s are easily installed in a variety of applications where -48VDC, 24VDC & 125VDC power is used as the primary power source. The- 48VDC, 24VDC & 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in hubs with a proven track record.

www . GarrettCom . com

47

Page 54
Image 54
GarrettCom manual Appendix B Internal DC Power Supply Option, B1.0 Specifications for Magnum 3000S