GarrettCom Magnum 3000 manual Rpm-Bnc, Rpm-Aui, Directly Magnum RPM-BNC

Models: Magnum 3000

1 59
Download 59 pages 6.23 Kb
Page 30
Image 30

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

4.2.1RPM-BNC

The Magnum RPM-BNC repeater module is equipped with a standard

10BASE2 coax connector. This RPM performs full IEEE 802.3 repeater functionality and is used for 10BASE2 ThinNet (commonly referred to as BNC) connections.

The RPM-BNC module is designed with a special switch-selectable internal termination function that eliminates the need for a "tee" connector and a 50 ohm terminator. To take advantage of internal termination, the slide switch should be in the "DOWN" (or right-side) position. In this configuration, the 10BASE2 segment is

directly

Magnum RPM-BNC

attached to the BNC port where it is internally terminated. When the switch is in the "UP" (or left-side) position, the BNC port requires a "tee" connector (not supplied) and a 50 ohm terminator for proper termination. Certain applications may require a "tee" connector, used as a tap, to allow the 10BASE2 coax segment to continue on past the RPM-BNC connection.

The RPM-BNC module includes one partition (PART) and one receive (RX) LED, which are visible beside the connector. The PART LED illuminates AMBER to indicate that the segment

has been automatically

Standard BNC

Internal Termination

Slide Switch

partitioned. As soon as

10BASE2 Connector

 

 

 

 

 

normal reception resumes,

 

1

Partition LED

 

 

the segment will be

 

2

Receive LED

automatically re-

 

1

 

 

established. The RX LED

 

2

 

 

 

 

illuminates GREEN

 

 

 

intermittently to indicate data is being received.

Important Note: for the RPM-BNC Termination Switch -

DOWN (or right) = Internally Terminated, UP (or left) = "T" Connector required.

4.2.2RPM-AUI

www . GarrettCom . com

23

Page 30
Image 30
GarrettCom Magnum 3000 manual Rpm-Bnc, Rpm-Aui, Directly Magnum RPM-BNC