GarrettCom Magnum 3000 manual Specifications Repeater Port Modules RPMs Bonus Ports

Models: Magnum 3000

1 59
Download 59 pages 6.23 Kb
Page 10
Image 10

Magnum 3000 Stackable Hubs

Installation and User Guide (07/06)

1.1Specifications - Repeater Port Modules (RPMs); Bonus Ports

RPM Type :

BNC

AUI

DTE

Fiber-mm Fiber-sgl.m

TP*

Front Access

yes

yes

yes

yes

yes

yes

Connector Type

BNC-f

DB-15 f

DB-15 m

Fiber-ST Fiber-ST

RJ-45

Partition (PART)LED

yes

yes

yes

yes

yes

yes

Receive (RX) LED

yes

yes

yes

yes

yes

yes

LINK LED

n.a.

n.a.

n.a.

yes

yes

yes

Switch on Face Plate

yes**

n.a.

n.a.

n.a.

n.a.

yes***

“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to 2.0Km.

“Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.

*The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

**Internal termination switch for BNC, no "T" connector is required.

***MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,

no crossover cable is required.

1.2Specifications - Bridge Port Modules (BPMs); Bonus Ports

BPM Type :

BNC

AUI

Fiber

TP*

Connector Type

BNC(f)

DB-15(f)

ST

RJ-45

Switch on FP

yes**

n.a.

n.a.

yes***

FWD-I LED

yes

yes

yes

yes

FWD-X LED

yes

yes

yes

yes

LINK LED

n.a.

n.a.

yes

yes

*The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

**Internal termination switch for BNC, no "T" connector is required.

***MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,

no crossover cable is required.

www . GarrettCom . com

3

Page 10