York YK M3 M3 G4 Section Microcomputer Control Center, Microcomputer Control Center and Keypad

Page 6

SECTION 2

MICROCOMPUTER CONTROL CENTER

26879A

LD00953

FIG. 3 – MICROCOMPUTER CONTROL CENTER AND KEYPAD

NOTE: This instruction covers operation of chillers equipped with Electro-Mechanical or Solid State Starters. If chiller is equipped with Variable Speed Drive, Form 160.00-O1 is to be used in conjunction with this manual.

WARNING

This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accor- dance with the instructions manual, may cause interference to radio communications. Operation of this equip- ment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever action may be required to correct the interference.

Additionally, any electronic equipment can generate EMI (electromagnetic interference) which, depending upon the installation and magnitude, may affect other electronic equipment. The amount of EMI generated is deter- mined by the source inductance, load inductance, and circuit impedances. Responsibility for assuring the satisfactory operation of other equipment included in the same power source as the YORK equipment rests solely with the user. YORK disclaims any liability resulting from any interference or for the correction thereof.

6

YORK INTERNATIONAL

Image 6
Contents Centrifugal Liquid Chillers With Microcomputer Control CenterTable of Contents Nomenclature Section Description of System and Fundamentals of OperationSystem Operation Description See Fig Detail a Compressor Prerotation Vanes Capacity ControlSection Microcomputer Control Center Microcomputer Control Center and KeypadIntroduction Condenser Refrigerant LevelControl Center OperationDisplaying System Parameters To Display Chilled Liquid Temperatures To Display OIL PressurePsid = HOP LP Offset Pressure To Display Motor Current To Display Operating Hours and Starts CounterSystem Setpoints See Programming System Setpoints, Displaying System Setpoints To Display Undervoltage setpoints Microcomputer Control Center Press Access Code keyProgramming Programming System SetpointsElectro-Mechanical Starter, refer to Fig Solid State Starter, refer to FigKeypad Programming Pull Down Demand Setpoint SetpointKeypad Programming Daily Schedule Setpoint Keypad Programming Holiday Service Keys PRE-ROTATION Vanes KeysOther Service Keys Pulldn Level = XXX% Setp = XXX% Actual = XXX%Operating Modes Compressor Switch Display MessagesSystem RUN Auto Vanes System Shutdown Messages When Control Center is in Remote mode MON Xxxx AM Evap Trans or Probe Error Function Jumper Position ThenTherefore MON Xxxx AM High Line Voltage MON Xxxx AM High Speed Drain Temp OIL Heaters Checking the OIL Level in the OIL System Operating ProceduresSTART-UP Procedure ReservoirSTART-UP Chiller OperationCondenser Water Temperature Control Chiller Starting Sequence & Shutdown SequenceChecking Operation EcwtLchwt Operating LOG SheetWeekly Operating Inspections See SectionDaily QuarterlySafety Shutdowns Need for Maintenance or ServiceNormal and Safety System Shutdowns Cycling ShutdownsProlonged Shutdown START-UP After Prolonged ShutdownSystem Components Description System ComponentsCompressor Lubrication System See Fig GeneralCompressor Speed Increasing GearsSchematic Drawing YK Compressor Lubrication System Heat Exchangers OIL HeaterMotor Driveline Refrigerant Flow ControlMicrocomputer Control Center See Section Solid State Starter OptionalVariable Speed Drive Optional Operational Maintenance OIL Return SystemChanging the Dehydrator OIL Charging Procedure OIL ChargeTroubleshooting RiseLEP Operating Setpoints System After Service Symptom High Cooler Pressure Operating Analysis ChartSymptom Abnormally LOW Suction Pressure Symptom no OIL Pressure When System Start Button PushedSymptom Reduced OIL Pump Capacity Symptom OIL Pump Vibrates or is NoisySymptom OIL Pump Fails to Deliver OIL Pressure OIL Pressure display keyMaintenance Leak Testing During OperationConducting R-22 Pressure Test Vacuum Testing System PressuresVacuum Dehydration OperationRefrigerant Charging Checking the Refrigerant Charge During Unit ShutdownRefrigerant Charge Handling Refrigerant for Dismantling and Repairs Megging the MotorMotor Stator Temperature and Insulation Resistances Condensers and Coolers Testing for Cooler and Condenser Tube Leaks Compressor Electrical ControlsCompressor Motor Preventive MaintenancePressure Testing Cooler and CondenserElectrical Controls ALL Rights Reserved

YK M3 M3 G4 THRU YK S6 S4 J2, YK LB LB G4 THRU YK SE SC J4, YK M3 M3 G4 specifications

The York YK M3 M3 G4, YK M3 M3 G4 THRU YK S6 S4 J2, and YK LB LB G4 THRU YK SE SC J4 represent a sophisticated line of HVAC systems engineered for modern commercial applications. These models are celebrated for their innovative designs, energy efficiency, and advanced features, making them a preferred choice among facility managers and building owners.

One of the standout characteristics of the York YK series is its modular construction, which provides unparalleled flexibility in system configuration. This design allows for easy upgrades and expansions as building demands evolve. The YK M3 series, in particular, is equipped with advanced controls that enhance system performance while minimizing energy consumption. With features like variable speed drives and sophisticated control algorithms, these units optimize airflow and refrigerant use, significantly reducing operational costs.

Another notable aspect of the YK M3 M3 G4 is its robust refrigeration technology. Utilizing high-efficiency scroll compressors, these chillers deliver impressive cooling capacities while maintaining high energy efficiency ratings. Integrated with low GWP (Global Warming Potential) refrigerants, they meet modern environmental standards, ensuring compliance with regulations while promoting sustainability.

The YK LB LB G4 and YK SE SC J4 models further enhance York’s portfolio with their compact designs and lower installation footprints. These chillers are ideal for applications where space is at a premium. Additional features include advanced noise reduction technology, allowing for quieter operation compared to traditional HVAC systems, making them suitable for urban environments or buildings where noise control is a priority.

Furthermore, York's commitment to continuous innovation is evident in the incorporation of smart technology across its chiller series. Features such as connectivity options for monitoring and diagnostics through mobile apps or web interfaces empower users to maintain optimal system performance proactively. This connectivity aids in predictive maintenance, enabling timely interventions that extend equipment life and reliability.

Finally, all these high-efficiency chillers are backed by York's renowned service support network, ensuring that customers have access to expert assistance and maintenance services whenever needed. With their exceptional features, modern technologies, and commitment to sustainability, the York YK M3 M3 G4, YK M3 M3 G4 THRU YK S6 S4 J2, and YK LB LB G4 THRU YK SE SC J4 models stand out as leaders in the commercial HVAC market, setting new standards for performance and efficiency.