York DM090 installation manual Detail B Detail a, Detail C

Page 13

035-17311-003-A-0704

Do not permit overhanging structures or shrubs to obstruct condenser air discharge outlet, combustion air inlet or vent outlets.

30-11/32

50-3/4

 

Power

Control

 

Entry

 

Entry

 

Ø7/8

 

Ø2-1/2

 

 

4-1/4

 

Power

 

 

Entry

 

 

Ø2-1/2

Convenience Power Outlet Entry Ø7/8

 

30-3/16

17-3/16

 

 

 

59

24-3/16

6-3/16

 

 

 

LEFT

27

ForBaserail

Dimensions

FRONT SeeDetailA

ForDrain

Dimensions

SeeDetailB

89

FIGURE 8 - UNIT DIMENSIONS

 

TABLE 6:

UNIT CLEARANCES

 

Top*

 

72”

Right

12”

Front

 

36”

Left

36”

 

 

 

 

 

Rear

 

36”

Bottom

0”

*. Units must be installed outdoors. Overhanging struc- ture or shrubs should not obstruct condenser air dis- charge outlet.

†.To remove the slide-out drain pan, a rear clearance of sixty inches is required. If space is unavailable, the drain pan can be removed through the front by separat- ing the corner wall.

‡.Units may be installed on combustible floors made from wood or class A, B or C roof covering materials.

NOTE: A one-inch clearance must be provided between any combustible material and the supply ductwork for a distance of 3 feet from the unit.

DETAIL B

2-3/8

 

 

3-3/4

3-9/16

DETAIL A

GasPipeInlet

 

DETAIL C

 

 

5-1/4

 

Base

5-3/8

 

17-13/16

 

 

Pan

 

 

 

 

 

ViewofWalAcrossfromCoil

 

 

Unitary Products Group

13

Image 13
Contents Installation Manual Table of Contents List of Figures List of Tables General Safety ConsiderationsInspection ReferenceNomenclature ½ 12½ Ton Predator Model Number NomenclatureNOMENCLATURE, Additonal Options Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Phase Monitor, & Coil Guard Installation Safety Information InstallationPreceding Installation Location Unit Temperature LimitationsRigging and Handling Length of Forks Must be a Minimum of 60 Inches Point Load WeightDetail C Detail B Detail aBottom Duct Openings from Above Duct Covers DuctworkSide Panels with Hole Plugs Condensate Drain Control Wire Sizes Thermostat WiringPower and Control Wiring Power Wiring DetailElectronic Thermostat Field Wiring RLA 380 11.5 75.0 Electrical Data DM120 10 TON with Power Convenience OutletPhysical Data OPTIONS/ACCESSORIESMinimum Supply AIR CFM Adjustments and Information Economizer and Power Exhaust SET PointEnthalpy SET Point Chart Blower Rotation PhasingSupply AIR Limitations Belt Tension1/2 TON Optional Motor Down Shot Blower PERFORMANCE* † 1/2 TON Standard Motor Down Shot Blower PERFORMANCE* †10 TON Optional Motor Down Shot Blower PERFORMANCE* † 10 TON Standard Motor Down Shot Blower PERFORMANCE* †12-1/2 TON Optional Motor Down Shot Blower PERFORMANCE* † 12-1/2 TON Standard Motor Down Shot Blower PERFORMANCE* †1/2 TON Optional Motor Side Shot Blower PERFORMANCE* † 1/2 TON Standard Motor Side Shot Blower PERFORMANCE* †10 TON Standard Motor Down Shot Blower PERFORMANCE* † 12-1/2 TON Optional Motor Side Shot Blower PERFORMANCE* † 12-1/2 TON Standard Motor Side Shot Blower PERFORMANCE* †AIR Balance Indoor Blower SpecificationsChecking AIR Quantity Method ONE Method TWODRY Coil Delta P Supply AIR Drive Adjustment Additional Static Resistance OperationMotor Sheave Datum Diameters Sequence of Operations OverviewCooling Sequence of Operation Compressor Protection Safety ControlsElectric Heat Limit Setting Electric Heating Operation ErrorsElectric Heating Sequence of Operations Electric Heat Antictpator SetpointsCharging the Unit START-UP Cooling12.5 TON Standard Efficiency Superheat Charging 10 TON Standard Efficiency Superheat ChargingGeneral Normal Maintenance TroubleshootingPredator Flash Codes Unit Control Board Flash Codes Basic Troubleshooting FlowchartCooling Troubleshooting Guide Unitary Products Group 035-17311-003-A-0704 Unitary 5005 Norman Products York Group Drive 73069