GB
Installation
To fix the extractor to the kitchen unit the pattern on page 19 is used.
The lower part of the extractor must be located at a minimum height of 60 cm above the hob for electric cookers and 65 cm for gas cookers. If the instruc- tions of a gas cooker indicate a greater distance these must be observed.
The extractor must be connected to a wall socket with an effective earth. When the extractor is working at the same time as other
To achieve optimum performance the length of the outlet hose should not exceed 4 meters, or include more than two 90º angles (elbows)
Although venting to the outside is rec- ommended, activated carbon filters may be used, which allow the gas to be returned to the kitchen through the out- let pipe.
If you wish to exchange the front for one matching the kitchen units, follow the following instructions:
-Withdraw the movable group.
-Remove the screws (T) that support the front
-Install the new front fixing it with the same screws that held the old one.
320 |
340 |
Ajuste Prof. Mueble
T |
T |
T |
If something does not work
Before seeking technical assistance car- ry out the following checks first.
Defect | Possible cause | Solution |
|
|
|
The extractor | The cable is not connected | Connect the mains cable |
does not work |
|
|
No current is reaching the plug | Revise/repair the | |
|
| electricity circuit |
The extractor does not | Filter saturated with grease | Clean or substitute filter |
blow enough or vibrates | Outlet obstructed | Eliminate obstructions |
| Inadequate air conduit | Contact the installer and follow |
|
| instructions of this manual |
The lamps do not light | Lamp broken | Exchange the bulb |
| Lamp loose | Tighten bulb |
|
|
|
18