Special U.K. Requirements
Height above gas hob: 75 mm minimum
NEVER PLACE THE COOKER HOOD OVER AN EYE-LEVEL GRILL.
This appliance must be connectec by a competent person, using fixed wiring via a DOUBLE POLE SWITCHED FUSED
SPUR OUTLET.
Electical connection
We recommend that the appliance is con- nected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations. Should the colour of the wires in the manis lead for the appliance not correspond with the coloured markings identifying the termi- nal in your spur box proceed as follows:
-The wire which is coloured blur must be connected to the marked N (Neutral) or coloured Black.
-The wire which is coloured brown must be connected to the marked L (Live) or couloured Red.
-Where avialable (see installation), the wire which is coloured yellow/green must be
connected to the market or coloured Yellow/Green.
If the cooker hood is installed for use above a gas appliance then the provision vor ven- tilation must be in accordance with the Gas Safety (Installation & Use) Regulations 1984 and the relevant Building Regula- tions. Detailed recommendations are con- tained in the following British Standard Codes of Practice BS6172, BS5440 and BS6891 Current Edition.
GB
Drilling pattern for installation in the kitchen unit
|
| 599 |
|
| 152 |
|
| A |
| 63 | 132 |
280 | B | |
214 | 132 | |
|
| |
| 4 x | 8 |
|
| 458 |
|
| 599 |
|
| C |
A
Outlet for two motors
B Outlet for single motor C Front of extractor
19