NuTone CV570, CV554, CV556 installation instructions Installation in Existing Construction

Page 10

INSTALLATION IN EXISTING CONSTRUCTION (continued)

MODEL 330N WALL INLET INSTALLATION (329 Rough-in)

1.Make cutout according to dimensions in Figure 34.

2.Refer to Figure 35. Break off nail plate at scored line.

3.Refer to Figure 36. Glue elbow to mounting plate, place assembly into cutout, and attach elbow to tubing inside the wall.

4.Make sure mounting holes are exactly at top and bottom.

5.Connect 2-conductor low voltage wire to terminal screws on back of wall inlet.

6.Refer to Figure 37. Align inlet mounting holes with mounting plate holes, place inlet into mounting plate, and secure with provided screws. NOTE: If 382-S shorter radius elbow is used, it may be necessary to use the short mounting screw to avoid interference with elbow.

1/4"

23/4"

3/8" DIA.

37/8"

 

3/8" DIA.

1/4"

13/8"

FIGURE 34

FIGURE 35

MOUNTING

PLATE

ELBOW

MOUNTING

HOLE (2)

FIGURE 36

INLET

MOUNTING

PLATE

FIGURE 37

FLOOR INLET INSTALLATION IN NEW & EXISTING CONSTRUCTION

MODEL 360 SERIES INLETS (361 Rough-in)

1.Refer to Figures 38 and 39. After floor inlet location has been selected, cut a 3116" x 2916" square hole in floor. Center line of inlet must be located at least 212" from wall to allow cover to be opened when hose is inserted.

2.Determine direction of tubing and attach appropriate flanged fitting to mounting bracket with four (4) screws supplied. Be sure mounting bracket flange does not interfere with tubing and seal is securely in place.

3.Refer to Figure 40. Position bracket with frame and flanged fitting assembly into cutout from below and secure to sub floor.

4.Refer to Figure 41. Large end of Model 399 extension sleeve should be cut to length to allow proper seating of inlet against floor or carpet.

5.Refer to Figure 42. Pull low-voltage 2-conductor wire through mounting bracket and attach to terminal screws on back of floor inlet. Cement extension sleeve to model 360 inlet. Insert extension sleeve through vinyl gasket in mounting bracket and firmly seat into flanged fitting.

6.For convenience of operation, floor inlet should be installed to open back toward wall.

7.Refer to Figure 40. Secure floor inlet in place with two screws.

TOP VIEW

 

29/16"

 

 

31/16"

 

FIGURE 38

MOLDING

WALL

 

 

 

SIDE VIEW

21/2" MIN.

 

 

APPROX.

 

 

MOUNTING BRACKET

 

 

FLANGE

FIGURE 39

 

 

10

Image 10
Contents Installation in NEW Construction Installation InstructionsInstallation in Existing Construction TWO-STORY House System Planning and LayoutRanch Style House SPLIT-LEVEL HouseTubing and Wall Inlet Locations Locating the Power UnitLocating Access Keys Existing Construction Stacked Closets or LaundryModel 361 for USE with 360 Inlets Installation in NEW ConstructionWall Inlet ROUGH-IN Model 329 for USE with 330 InletsInstallation in NEW Construction Installing the TubingTube to prevent this condition. Refer to Figure Wall Inlet InstallationModel 360 Wall Inlet 361 Rough-In Model 330 Wall Inlet 329 Rough-inInstallation in NEW Construction Dimensional Chart Power Unit InstallationTubing Connections AT Power Unit Minimum Wall Clearance DimensionsModel 360 Series Inlets 361 Rough-In Installation in Existing ConstructionThan 1⁄2, a spacer must be used. See on page 6 as Guide Installation in Existing Construction Model 330N Wall Inlet Installation 329 Rough-inFinal System Check Installation Dans UNE Construction Existante Instructions ’INSTALLATIONInstallation DU Groupe D’ASPIRATION Installation DES Prises AU SOLLA Maison a UN Etage Planification ET Disposition DU SystemeLA Maison a Plusieurs Niveaux Tuyauterie ET Emplacement DES Prises Murales Emplacement DU Groupe D’ASPIRATIONModele 361 Convient AUX Prise Installation Dans UNE Nouvelle ConstructionEncastrement DE Prise Murale Modele 329 Convient AUX PrisesInstallation Dans UNE Nouvelle Construction suite Installation DE LA TuyauterieInstallation DES Prises Murales Modele 360 Prise Murale EncastrementVue de derrier Tableau DES Dimensions Installation DU Groupe DaspirationDégagement Minimum AU MUR Installation DES Prises Murale Modele CI370 OU Serie 360 DE Prises EncastrementInstallation Dans UNE Construction Existante suite Installation DE Prise Murale Modele 330N EncastrementInstallation DES Prises AU SOL Verification Finale DU SystemeTwo Year Limited Warranty