NuTone CV554, CV570, CV556 Wall Inlet Installation, Model 360 Wall Inlet 361 Rough-In

Page 6

INSTALLATION IN NEW CONSTRUCTION (continued)

 

WALL INLET INSTALLATION

 

 

 

MODEL 360 WALL INLET (361 Rough-In)

 

 

 

1. Remove the cardboard plaster guard.

 

 

 

2. Refer to Figure 17. For some drywall or panel construction, the

 

 

 

plaster frame will extend beyond the finished wall. In this case,

 

 

 

remove plaster frame from mounting bracket by removing

 

 

 

mounting screws.

 

 

 

NOTE: When using the Model 361 inlet bracket on walls thinner

 

 

 

than 12", use a 14" spacer (not furnished) between the wall and the

FIGURE 17

 

FIGURE 18

inlet bracket. See Figure 20. Spacer may be made from plywood,

 

 

 

 

Masonite™, etc. Contact cement may be used to hold spacer in

 

 

 

place during assembly. Configuration of spacer may vary

 

 

 

depending upon installation.

 

 

 

3. Refer to Figure 18. Connect 2-conductor low voltage wire to

 

 

 

terminal screws on back of wall inlet. Cap off both wires using

 

 

 

wire nut (supplied).

 

 

 

4. Guide excess wire back through the hole in inlet bracket and

 

 

 

flanged fitting

 

 

 

5. Refer to Figure 19. Place inlet into mounting bracket and

 

 

 

secure.

FIGURE 19

 

 

NOTE: when wall inlets are installed in walls that are less

 

 

 

than 12" thick or when inlets are installed back-to-back in a

INLET MOUNTING

SPACER

WALL LESS THAN

wall, the tube of the wall inlet may extend into elbow area of

 

1/4"

1/2" THICK.

BRACKET

the flanged fitting and cause blockage. Shorten the wall inlet

 

 

 

 

 

tube to prevent this condition. Refer to Figure 21.

 

 

 

For extra thick walls, use Model 399 Extension Sleeve to connect inlet to the flanged fitting.

MODEL 330 WALL INLET (329 Rough-in)

2

1

/4"

31/4"

PLASTER

See Figure 23.

 

 

GUARD

FIGURE 20

 

 

 

HOLE

1.

Connect 2-conductor low voltage wire to terminal screws on

 

 

 

 

 

 

 

 

 

 

back of wall inlet.

 

 

 

MODEL 365

 

2.

Align inlet mounting holes with holes in mounting plate.

 

 

 

 

 

 

 

DOUBLE FLANGED

3.

Place inlet into mounting plate and secure with two provided

 

 

 

TEE

WALL

 

 

 

 

 

screws.

 

 

 

 

INLET

 

 

 

 

 

 

WALL

SHORTEN

MOUNTING

FIGURE 21

 

BRACKET

 

INLET

MOUNTING

 

 

 

 

PLATE

6

 

FIGURE 22

 

 

Image 6
Contents Installation Instructions Installation in NEW ConstructionInstallation in Existing Construction TWO-STORY House System Planning and LayoutRanch Style House SPLIT-LEVEL HouseTubing and Wall Inlet Locations Locating the Power UnitLocating Access Keys Existing Construction Stacked Closets or LaundryModel 361 for USE with 360 Inlets Installation in NEW ConstructionWall Inlet ROUGH-IN Model 329 for USE with 330 InletsInstallation in NEW Construction Installing the TubingTube to prevent this condition. Refer to Figure Wall Inlet InstallationModel 360 Wall Inlet 361 Rough-In Model 330 Wall Inlet 329 Rough-inInstallation in NEW Construction Dimensional Chart Power Unit InstallationTubing Connections AT Power Unit Minimum Wall Clearance DimensionsInstallation in Existing Construction Model 360 Series Inlets 361 Rough-InThan 1⁄2, a spacer must be used. See on page 6 as Guide Installation in Existing Construction Model 330N Wall Inlet Installation 329 Rough-inFinal System Check Installation Dans UNE Construction Existante Instructions ’INSTALLATIONInstallation DU Groupe D’ASPIRATION Installation DES Prises AU SOLPlanification ET Disposition DU Systeme LA Maison a UN EtageLA Maison a Plusieurs Niveaux Tuyauterie ET Emplacement DES Prises Murales Emplacement DU Groupe D’ASPIRATIONModele 361 Convient AUX Prise Installation Dans UNE Nouvelle ConstructionEncastrement DE Prise Murale Modele 329 Convient AUX PrisesInstallation Dans UNE Nouvelle Construction suite Installation DE LA TuyauterieInstallation DES Prises Murales Modele 360 Prise Murale EncastrementVue de derrier Installation DU Groupe Daspiration Tableau DES DimensionsDégagement Minimum AU MUR Installation DES Prises Murale Modele CI370 OU Serie 360 DE Prises EncastrementInstallation Dans UNE Construction Existante suite Installation DE Prise Murale Modele 330N EncastrementInstallation DES Prises AU SOL Verification Finale DU SystemeTwo Year Limited Warranty