NuTone CV570, CV554, CV556 installation instructions Installation in NEW Construction

Page 7

INSTALLATION IN NEW CONSTRUCTION (continued)

CI-390 ELECTRAVALVE™ ELECTRIFIED INLET INSTALLATION (CI-390RK Rough-In) (Not available in Canada)

1.See Figure 23. Fasten the mounting plate to a stud within three studs (48") of an electrical outlet box. Measure and mark the wire 10" from the plug (A). Feed the wire through the top hole in the mounting plate (just above the circular opening). Snap the molded plug into the mounting plate as pictured (B). This will keep it secure and out of harm’s way during drywalling and finishing. Line up the wire at the previously measured 10" mark with the strain of relief channel on the back of the mounting plate. Secure it in place with the supplied wire tie (C).

2.Run the inlet wire to the adjacent electric box. If you must run wire through a stud, drill directly through the center of the stud (D).

3.See Figure 24. Place the exposed ends of the two wires into the electrical box through a strain relief channel (E). Tighten the strain relief channel (do not overtighten) on the white sheathing leaving 1/2" of this sheathing exposed inside of the outlet box.

Fold the 6" of black and white wire into the outlet box. Leave the wires to be connected by the electrician when plug receptacles are being installed. (Attention: Power tools such as routers are not recommended for use with the inlet installation, as removal of drywall with these devices may cause damage to the mounting plate and/or inlet plug).

4.Once drywall and finishing processes have been completed, remove molded plug from mounting plate (with the aid of a slot screwdriver) and snap it into the wing slot at the back of the inlet (F). (Please note: molded plug fits one way only, with the narrow opening at the top). Insert inlet into the mounting plate and secure inlet to mounting plate with screws provided.

NOTE: All electrical devices such as the electrified inlet should be reported to the construction electrician for listing on the inspection report for building inspection purposes.

NOTE: Plumb inlet to tubing using NuTone

Model 382-S90° Ell fitting.

FIGURE 23

E

D

FIGURE 24

7

Image 7
Contents Installation in NEW Construction Installation InstructionsInstallation in Existing Construction SPLIT-LEVEL House System Planning and LayoutRanch Style House TWO-STORY HouseStacked Closets or Laundry Locating the Power UnitLocating Access Keys Existing Construction Tubing and Wall Inlet LocationsModel 329 for USE with 330 Inlets Installation in NEW ConstructionWall Inlet ROUGH-IN Model 361 for USE with 360 InletsInstalling the Tubing Installation in NEW ConstructionModel 330 Wall Inlet 329 Rough-in Wall Inlet InstallationModel 360 Wall Inlet 361 Rough-In Tube to prevent this condition. Refer to FigureInstallation in NEW Construction Minimum Wall Clearance Dimensions Power Unit InstallationTubing Connections AT Power Unit Dimensional ChartModel 360 Series Inlets 361 Rough-In Installation in Existing ConstructionThan 1⁄2, a spacer must be used. See on page 6 as Guide Model 330N Wall Inlet Installation 329 Rough-in Installation in Existing ConstructionFinal System Check Installation DES Prises AU SOL Instructions ’INSTALLATIONInstallation DU Groupe D’ASPIRATION Installation Dans UNE Construction ExistanteLA Maison a UN Etage Planification ET Disposition DU SystemeLA Maison a Plusieurs Niveaux Emplacement DU Groupe D’ASPIRATION Tuyauterie ET Emplacement DES Prises MuralesModele 329 Convient AUX Prises Installation Dans UNE Nouvelle ConstructionEncastrement DE Prise Murale Modele 361 Convient AUX PriseInstallation DE LA Tuyauterie Installation Dans UNE Nouvelle Construction suiteModele 360 Prise Murale Encastrement Installation DES Prises MuralesVue de derrier Tableau DES Dimensions Installation DU Groupe DaspirationDégagement Minimum AU MUR Modele CI370 OU Serie 360 DE Prises Encastrement Installation DES Prises MuraleInstallation DE Prise Murale Modele 330N Encastrement Installation Dans UNE Construction Existante suiteVerification Finale DU Systeme Installation DES Prises AU SOLTwo Year Limited Warranty