NuTone CV556, CV554, CV570 Installation in NEW Construction, Installing the Tubing

Page 5

INSTALLATION IN NEW CONSTRUCTION (continued)

INSTALLING THE TUBING

Use the following installation guidelines when installing tubing.

1.Start tubing installation at farthest inlet and work toward the power unit.

2.Tubing run to the power unit should be as straight as possible.

3.When assembling sections with elbows and tees, make sure the curve in the fitting is aligned so that the air flows toward the power unit.

4.Branch lines should always join the trunk line from above or from the same level. Never join a branch line from an angle below the trunk line.

5.Refer to Figure 28 on page 8. Run low voltage wiring (Model 376-UL) and secure wiring to tubing as tubing is installed. Model CF-380 Pipe Support can be used to support long runs of tubing (position near joists) and to clip wire along tubing. Secure tubing to joists or studs. Leave approximately 6" of wire for connection to each inlet.

6.Cut a 212" diameter hole in sole plate, header or stud directly in line with opening of inlet bracket fitting.

Note Figure 6 for center line dimensions.

7.Refer to Figure 11. Measure length of tubing needed to connect inlet to trunk line. Allow approximately 34" of tubing for inserting into fittings.

8.Refer to Figure 12. Cut tubing, keeping cut square.

9.Refer to Figure 13. Remove burrs from both inside and outside of tubing.

10.Before cementing, pre-assemble section to inlet fitting, check for proper length.

 

MODEL 361 MOUNTING

 

 

21/2" DIA. HOLE

 

 

THROUGH SOLE PLATE

 

2 3/8"

 

113/16"

 

113/16"

113/16"

SIDE

 

FACE

MOUNTING

 

MOUNTING

 

MODEL 329 MOUNTING

 

 

2"

21/2" DIA. HOLE

 

THROUGH SOLE PLATE

 

 

2" - 382S

 

FACE

258" - 382

FIGURE 10

MOUNTING

 

 

INCLUDE FITTING

 

 

RECESS IN

 

 

MEASUREMENT

3/4"

3/4"

TUBING MEASUREMENT

 

 

FITTING

PVC TUBING

FITTING

 

 

FIGURE 11

 

 

11.Refer to Figure 14. Apply PVC cement (Model 379) to outside of tubing. Coat tubing approximately 1" back. Take care to keep cement from inside of tube.

12.Refer to Figure 15. Insert tubing into fitting with a twisting motion to evenly spread cement. Be sure tubing is firmly seated in fitting.

13.If fittings have been attached to tubing at the end opposite the inlet bracket, be sure alignment is proper before cement sets.

14.Refer to Figure 16. Tape wire to tubing to hold in place and insert through hole in inlet bracket.

15.Connect each inlet line and branch line into main trunk line. Complete low voltage wiring as main trunk line is continued back to power unit.

FIGURE 12

FIGURE 13

Caution: When tubing is run through the wall stud, sole plate, headers - or anywhere that building materials will be attached - place a nail plate (Model 378) over that area

(on both sides if necessary) to prevent nails from piercing tubing.

FIGURE 14

FIGURE 15

FIGURE 16

5

Image 5
Contents Installation in Existing Construction Installation InstructionsInstallation in NEW Construction Ranch Style House System Planning and LayoutTWO-STORY House SPLIT-LEVEL HouseLocating Access Keys Existing Construction Locating the Power UnitTubing and Wall Inlet Locations Stacked Closets or LaundryWall Inlet ROUGH-IN Installation in NEW ConstructionModel 361 for USE with 360 Inlets Model 329 for USE with 330 InletsInstalling the Tubing Installation in NEW ConstructionModel 360 Wall Inlet 361 Rough-In Wall Inlet InstallationTube to prevent this condition. Refer to Figure Model 330 Wall Inlet 329 Rough-inInstallation in NEW Construction Tubing Connections AT Power Unit Power Unit InstallationDimensional Chart Minimum Wall Clearance DimensionsThan 1⁄2, a spacer must be used. See on page 6 as Guide Installation in Existing ConstructionModel 360 Series Inlets 361 Rough-In Model 330N Wall Inlet Installation 329 Rough-in Installation in Existing ConstructionFinal System Check Installation DU Groupe D’ASPIRATION Instructions ’INSTALLATIONInstallation Dans UNE Construction Existante Installation DES Prises AU SOLLA Maison a Plusieurs Niveaux Planification ET Disposition DU SystemeLA Maison a UN Etage Emplacement DU Groupe D’ASPIRATION Tuyauterie ET Emplacement DES Prises MuralesEncastrement DE Prise Murale Installation Dans UNE Nouvelle ConstructionModele 361 Convient AUX Prise Modele 329 Convient AUX PrisesInstallation DE LA Tuyauterie Installation Dans UNE Nouvelle Construction suiteModele 360 Prise Murale Encastrement Installation DES Prises MuralesVue de derrier Dégagement Minimum AU MUR Installation DU Groupe DaspirationTableau DES Dimensions Modele CI370 OU Serie 360 DE Prises Encastrement Installation DES Prises MuraleInstallation DE Prise Murale Modele 330N Encastrement Installation Dans UNE Construction Existante suiteVerification Finale DU Systeme Installation DES Prises AU SOLTwo Year Limited Warranty