POWER UNIT INSTALLATION
MINIMUM WALL CLEARANCE DIMENSIONS | |
18" | 18" |
INTAKE | EXHAUST |
A | CONVENIENCE |
| OUTLET |
| TOP VIEW |
12" MINIMUM TO CEILING | |
| FRONT VIEW |
| C |
| ® |
| E |
B |
|
OVERALL |
|
HEIGHT |
|
| CONVENIENCE |
INTAKE | OUTLET |
18" MINIMUM ABOVE FLOOR | |
(MORE IS RECOMMENDED) | |
| FIGURE 25 |
DIMENSIONAL CHART
DIMENSION | CV554 | CV556 | CV570 |
A | 113⁄4" | 113⁄4" | 151⁄8" |
B | 40 3⁄8" | 411⁄4" | 39" |
C | 4 3⁄4" | 6" | 4 3⁄8" |
D | 2 3⁄8" | 21⁄2" | 5" |
E | 17 7⁄8" | 181⁄2" | 201⁄2" |
F | 15 1⁄2" | 151⁄2" | 151⁄2" |
BACK VIEW |
C |
D |
MOUNTING |
BRACKET |
F |
FIGURE 26 |
8 |
MOUNTING See Figure 25. Also refer to page 3.
1.Locate power unit within six feet of a grounded electrical outlet.
2.Remove mounting bracket from power unit and attach to wall, following minimum clearances noted in Figure 25. Screws must be secured into a wall stud or other suitable support.
3.Hang power unit securely on bracket.
TUBING CONNECTIONS AT POWER UNIT
1.Use black rubber connectors and hose clamps to connect intake and exhaust tubing.
2.Connect intake tubing to intake tube on power unit.
3.Connect exhaust tubing to upper exhaust tube on power unit.
4.Make sure all tubing connections are securely fastened.
5.An optional muffler (Model 392) may be installed to reduce motor noise.
6.The exhaust should not be vented into a wall, ceiling or concealed space in the house. Exterior vented exhaust lines should be term- inated using Model 393 Wall Caps or appropriate louvered exhaust vents.
WIRING See Figure 27.
Grounding Instructions – This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current, to reduce the risk of electric shock. This appliance is equipped with a cord having an
Danger – Improper connection of the
This appliance is for use on a nominal 120 volt circuit and has a grounding plug. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.
1.Connect low voltage wire (18 gauge,
2.The power unit is equipped with a six foot grounded cord. Plug cord into 120 volt grounded receptacle.
WIRING |
|
|
| 120 VAC | ||
|
|
|
|
| ELECTRICAL | |
|
|
|
|
| OUTLET | |
NOTE: INLET |
|
|
|
| ||
LEADS CONNECT |
|
| POWER |
| ||
CONNECTORS |
|
| ||||
TO POWER UNIT | POWER | CORD | MODEL | |||
|
| |||||
USING |
|
| UNIT |
| ||
|
|
|
| OR | ||
CONNECTORS |
|
|
|
| ||
|
|
|
| 376 | ||
SUPPLIED ON |
|
|
|
| (181⁄2) WIRE | |
POWER UNIT |
|
|
|
|
| |
TO |
|
|
|
|
| |
OTHER |
|
|
|
|
| |
INLETS |
|
|
|
|
| |
| INLET | INLET | INLET | FIGURE 27 | ||
|
|