NuTone CV556, CV554 Power Unit Installation, Tubing Connections AT Power Unit, Dimensional Chart

Page 8

POWER UNIT INSTALLATION

MINIMUM WALL CLEARANCE DIMENSIONS

18"

18"

INTAKE

EXHAUST

A

CONVENIENCE

 

OUTLET

 

TOP VIEW

12" MINIMUM TO CEILING

 

FRONT VIEW

 

C

 

®

 

E

B

 

OVERALL

 

HEIGHT

 

 

CONVENIENCE

INTAKE

OUTLET

18" MINIMUM ABOVE FLOOR

(MORE IS RECOMMENDED)

 

FIGURE 25

DIMENSIONAL CHART

DIMENSION

CV554

CV556

CV570

A

1134"

1134"

1518"

B

40 38"

4114"

39"

C

4 34"

6"

4 38"

D

2 38"

212"

5"

E

17 78"

1812"

2012"

F

15 12"

1512"

1512"

BACK VIEW

C

D

MOUNTING

BRACKET

F

FIGURE 26

8

MOUNTING See Figure 25. Also refer to page 3.

1.Locate power unit within six feet of a grounded electrical outlet.

2.Remove mounting bracket from power unit and attach to wall, following minimum clearances noted in Figure 25. Screws must be secured into a wall stud or other suitable support.

3.Hang power unit securely on bracket.

TUBING CONNECTIONS AT POWER UNIT

1.Use black rubber connectors and hose clamps to connect intake and exhaust tubing.

2.Connect intake tubing to intake tube on power unit.

3.Connect exhaust tubing to upper exhaust tube on power unit.

4.Make sure all tubing connections are securely fastened.

5.An optional muffler (Model 392) may be installed to reduce motor noise.

6.The exhaust should not be vented into a wall, ceiling or concealed space in the house. Exterior vented exhaust lines should be term- inated using Model 393 Wall Caps or appropriate louvered exhaust vents.

WIRING See Figure 27.

Grounding Instructions – This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current, to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Danger – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use on a nominal 120 volt circuit and has a grounding plug. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.

1.Connect low voltage wire (18 gauge, 2-conductor, Model 376-UL or 376) to crimp connectors located on outside of the power unit.

2.The power unit is equipped with a six foot grounded cord. Plug cord into 120 volt grounded receptacle.

WIRING

 

 

 

120 VAC

 

 

 

 

 

ELECTRICAL

 

 

 

 

 

OUTLET

NOTE: INLET

PUSH-ON

 

 

 

 

LEADS CONNECT

 

 

POWER

 

CONNECTORS

 

 

TO POWER UNIT

POWER

CORD

MODEL

 

 

USING PUSH-ON

 

 

UNIT

 

376-UL

 

 

 

 

OR

CONNECTORS

 

 

 

 

 

 

 

 

376

SUPPLIED ON

 

 

 

 

(1812) WIRE

POWER UNIT

 

 

 

 

 

TO

 

 

 

 

 

OTHER

 

 

 

 

 

INLETS

 

 

 

 

 

 

INLET

INLET

INLET

FIGURE 27

 

 

Image 8
Contents Installation in Existing Construction Installation InstructionsInstallation in NEW Construction System Planning and Layout Ranch Style HouseTWO-STORY House SPLIT-LEVEL HouseLocating the Power Unit Locating Access Keys Existing ConstructionTubing and Wall Inlet Locations Stacked Closets or LaundryInstallation in NEW Construction Wall Inlet ROUGH-INModel 361 for USE with 360 Inlets Model 329 for USE with 330 InletsInstallation in NEW Construction Installing the TubingWall Inlet Installation Model 360 Wall Inlet 361 Rough-InTube to prevent this condition. Refer to Figure Model 330 Wall Inlet 329 Rough-inInstallation in NEW Construction Power Unit Installation Tubing Connections AT Power UnitDimensional Chart Minimum Wall Clearance DimensionsThan 1⁄2, a spacer must be used. See on page 6 as Guide Installation in Existing ConstructionModel 360 Series Inlets 361 Rough-In Installation in Existing Construction Model 330N Wall Inlet Installation 329 Rough-inFinal System Check Instructions ’INSTALLATION Installation DU Groupe D’ASPIRATIONInstallation Dans UNE Construction Existante Installation DES Prises AU SOLLA Maison a Plusieurs Niveaux Planification ET Disposition DU SystemeLA Maison a UN Etage Tuyauterie ET Emplacement DES Prises Murales Emplacement DU Groupe D’ASPIRATIONInstallation Dans UNE Nouvelle Construction Encastrement DE Prise MuraleModele 361 Convient AUX Prise Modele 329 Convient AUX PrisesInstallation Dans UNE Nouvelle Construction suite Installation DE LA TuyauterieInstallation DES Prises Murales Modele 360 Prise Murale EncastrementVue de derrier Dégagement Minimum AU MUR Installation DU Groupe DaspirationTableau DES Dimensions Installation DES Prises Murale Modele CI370 OU Serie 360 DE Prises EncastrementInstallation Dans UNE Construction Existante suite Installation DE Prise Murale Modele 330N EncastrementInstallation DES Prises AU SOL Verification Finale DU SystemeTwo Year Limited Warranty