NuTone CV570, CV554, CV556 Installation in NEW Construction, Wall Inlet ROUGH-IN

Page 4

INSTALLATION IN NEW CONSTRUCTION

WALL INLET ROUGH-IN

Once the locations for wall inlets have been determined, mount all inlet brackets.

1.Choose the appropriate mounting bracket for the inlet being installed. (See chart.)

NuTone Inlet

Rough-in

330 Series

329

360 Series

361

CI390 Series Electrified Inlet

CI390RK

 

 

2.To locate bracket on wall stud, measure approximately 18" up from finished floor level. (Height may vary according to individual preference.)

MODEL 361 (FOR USE WITH 360 INLETS)

3.Refer to Figure 7. Nail bracket to side of stud so that front edge of bracket is flush to front of stud. (The bracket may also be nailed to the front edge of the stud. See face mounting illustrated. For face mounting, use locating tabs on bracket for proper alignment.)

4.Refer to Figure 8. Remove cardboard from plaster guard frame. Using four (4) provided screws, attach the appropriate flanged fitting and inlet seal to back of inlet.

5.Replace cardboard in plaster guard frame.

MODEL 329 (FOR USE WITH 330 INLETS)

6.When using Model 329, glue elbow to mounting plate. Attach to stud as shown in Figure 9.

MODEL 361

SIDEFACE

MOUNTINGMOUNTING

2 3/8"

 

 

 

113 /16"

 

 

FIGURE 7

FIGURE 8

M

TH

2 3/8"

SIDE

MOUNTING

M

FIGURE 9

4

Image 4
Contents Installation in NEW Construction Installation InstructionsInstallation in Existing Construction System Planning and Layout Ranch Style HouseTWO-STORY House SPLIT-LEVEL HouseLocating the Power Unit Locating Access Keys Existing ConstructionTubing and Wall Inlet Locations Stacked Closets or LaundryInstallation in NEW Construction Wall Inlet ROUGH-INModel 361 for USE with 360 Inlets Model 329 for USE with 330 InletsInstallation in NEW Construction Installing the TubingWall Inlet Installation Model 360 Wall Inlet 361 Rough-InTube to prevent this condition. Refer to Figure Model 330 Wall Inlet 329 Rough-inInstallation in NEW Construction Power Unit Installation Tubing Connections AT Power UnitDimensional Chart Minimum Wall Clearance DimensionsModel 360 Series Inlets 361 Rough-In Installation in Existing ConstructionThan 1⁄2, a spacer must be used. See on page 6 as Guide Installation in Existing Construction Model 330N Wall Inlet Installation 329 Rough-inFinal System Check Instructions ’INSTALLATION Installation DU Groupe D’ASPIRATIONInstallation Dans UNE Construction Existante Installation DES Prises AU SOLLA Maison a UN Etage Planification ET Disposition DU SystemeLA Maison a Plusieurs Niveaux Tuyauterie ET Emplacement DES Prises Murales Emplacement DU Groupe D’ASPIRATIONInstallation Dans UNE Nouvelle Construction Encastrement DE Prise MuraleModele 361 Convient AUX Prise Modele 329 Convient AUX PrisesInstallation Dans UNE Nouvelle Construction suite Installation DE LA TuyauterieInstallation DES Prises Murales Modele 360 Prise Murale EncastrementVue de derrier Tableau DES Dimensions Installation DU Groupe DaspirationDégagement Minimum AU MUR Installation DES Prises Murale Modele CI370 OU Serie 360 DE Prises EncastrementInstallation Dans UNE Construction Existante suite Installation DE Prise Murale Modele 330N EncastrementInstallation DES Prises AU SOL Verification Finale DU SystemeTwo Year Limited Warranty