Page 23

For Standing Pilot Model with Robertshaw Gas Valve, On/Off Operation

1.STOP! Read the safety information above.

2.Set the tankstat on the lowest setting.

3.Turn OFF all electric power to the heater.

4.Remove heater door panel.

5.Push in gas control knob slightly and turn clock- wise to "OFF".

GASCONTROL

KNOBSHOWN

IN"OFF"POSITION

GASINLET

Fig. 20: Robertshaw Gas Valve

NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If your smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7.Locate pilot mounted on the right side of the burn- er drawer, right of first burner.

8.Turn knob on gas control counter-clockwise to "Pilot".

9.Push in control knob all the way and hold in, immediately light the pilot with a match. Continue to hold control knob in for about one minute after the pilot is lighted, release knob and it will pop back up. Pilot should remain lighted. If it goes out, repeat steps 4 through 8.

* If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

*If the pilot does not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.Stand to the side of the heater and turn the gas control knob counter-clockwise to "ON".

11.Replace heater door.

12.Turn "ON" all electrical power to the heater.

13.Set the tankstat to the desired setting.

For Standing Pilot Model with Honeywell Gas Valve, On/Off Operation

1.STOP! Read the safety information.

2.Set the tankstat to the lowest setting.

3.Turn Off all electrical power to the heater.

4.Remove heater door panel.

5.Turn gas control knob clockwise to "OFF".

GASCONTROL

KNOBSHOWN

IN"OFF"

POSITION

GASINLET

Fig. 22: Honeywell Gas Valve

HONEYWELLPILOT

ROBERTSHAW PILOT

 

 

Fig. 21: Honeywell and Robertshaw Pilots

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7.Locate pilot mounted on the right side of the burn- er drawer, right of first burner.

8.Turn knob on gas control counter-clockwise to "PILOT".

9.Push down and hold the red reset button in, imme- diately light the pilot with a match. Continue to hold down red reset button for about one minute after the pilot is lighted. Release red reset button and it will pop back up. Pilot should remain lighted. If it goes out, repeat steps 4 through 8.

23

Image 23
Contents Econopak Water Heaters Page Contents Are important but not related to personal injury hazards Temperature Time to Produce Serious Burn General SafetyTime/Temperature Relationships in Scalds Receiving Equipment General SpecificationsTank Clearances InstallationCode Requirements Mounting BaseModel No Sq. in. of Each Free Area Venting ConnectionsOutdoor Models ModelsModels 0260 Indoor ModelsVent Terminal/Indoor Stack Installation Vent Max Model No Connector Horizontal Diameter Length ftVent Pipe Draft Hood Heater Common VentsModel No Nat Pro Gas Supply ConnectionsGas Pressure Regulator Gas Pressure Specifications Type Inches WC Regulator MinSetting Water Connections & System Piping0261 Low NOx WH1 with Pressure Relief Valve Relief ValveElectrical Wiring Standing Pilot Model Wiring DiagramsIntermittent Ignition Device IID Model Intermittent Ignition Device IID Models 0330 Intermittent Ignition Device IID Model 0261 Low NOx Intermittent Ignition Device IID Models 0331 & 0401 Low NOx Sequence of Operation Servicing ProceduresStart-up Procedures Honeywellpilot Robertshaw Pilot For Robertshaw Gas Valve Turn gas control System Shut Down ProcedureFor Automatic Ignition Models To Turn Off Gas To Appliance Testing the Ignition Safety Shut-offBurners Inspection ProceduresControls Low NOx Heaters-ModelsVisual Inspection Burner AdjustmentHigh/Low Gas Pressure Switch OperationRepair Section Combustion Chamber Removal Heat Exchanger Re-assemblyHeat Exchanger Removal Causes TroubleshootingPiping Intermittent Pilot System- Honeywell S8600 Electrical Electronic Ignition IIDElectrical Standing Pilot Adjustments & Replacement of Components Procedure for Cleaning Flue Gas Passage Ways Circulator ReplacementControl Well Replacement Tube Replacement ProcedureLimitedpartswarrantyeconopakwaterheaters Page Page