MULTIPLE ZONES WITH CIRCULATORS

 

AIR

12" MAX.

 

 

 

VENT

 

 

AIR

 

 

SCOOP

 

 

DIAPHRAGM

 

FEED

EXPANSION

 

TANK

 

VALVE PIPE PRESSURE

 

 

RELIEF VALVE

 

 

TO DRAIN

 

CIRCULATORS

COLD

 

WATER

INLET

HEATING UNITS

Fig. #8999.1

MULTIPLE ZONES WITH CIRCULATORS

AIR

VENT

AIR

SCOOP

DIAPHRAGM

EXPANSION

FEED TANK

VALVE

PIPE PRESSURE

RELIEF VALVE

TO DRAIN

 

COLD

ZONE

WATER

VALVES

INLET

 

HEATING UNITS

Fig. #9000.1

MULTIPLE ZONES WITH ZONE VALVES

14

Image 14
Contents 0042B, 0066B,0090B 0135B, 0180B FOR YOUR SAFETYRaythermTM Type H RESIDENTIAL BOILERS Models INSTALLATION AND OPERATING INSTRUCTIONSINSTALLATION PROCEDURES ContentsGENERAL SPECIFICATIONS SERVICING PROCEDURESGENERAL SPECIFICATIONS RECEIVING EQUIPMENTMOUNTING BASE 3. INSTALLATION PROCEDURESCODE REQUIREMENTS CLEARANCEREQUIREMENTSVENTING CONNECTIONS COMMON VENTS VENT DAMPER INSTALLATION Hole in Vent Damper Blade Closed Position VENT DAMPER OPERATION FLAIR DAMPERVENT DAMPER WIRING DIAGRAM WATER CONNECTIONS & SYSTEM PIPING GAS SUPPLY CONNECTIONSGASPRESSURE PIPING DIAGRAMS SINGLE-ZONEPIPINGZONE VALVES HEATINGUNITS ZONE HEATING WITH INDIRECT DOMESTICHOT WATER SUPPLY AIR SCOOP DIAPHRAGM EXPANSION FEED TANK VALVEMULTIPLE ZONES WITH CIRCULATORS MULTIPLE ZONES WITH ZONE VALVESELECTRICAL WIRING WIRING DIAGRAM KEYWIRING DIAGRAMS Page Page WIRING DIAGRAM Dual-ZoneHoneywell Valve WIRING DIAGRAM Single-ZoneTaco ValveWIRING DIAGRAM Dual-ZoneTaco Valve Fig. # 2228eFig. #2232e WIRING DIAGRAM System with 3 Zone PumpsWIRING DIAGRAM: Power Vent System w/ Zone Valve Fig. #2233e Fig. #2234eFig. #2223.2e WIRING DIAGRAM Primary/Secondary Pumping SystemHoneywell Zone Valve Note Low water cut-offLWCO and system switch supplied by others SERVICING PROCEDURES GENERAL LOCATION OF CONTROLSFilling the System START-UPPROCEDURES Lighting the BoilerFor Standing Pilot Models Checking the CirculatorTO TURN OFF GAS TO THE BOILER Models HONEYWELL PILOTROBERTSHAW PILOT FOR AUTOMATIC IGNITION MODELS3.For Honeywell valve SHUT-DOWNPROCEDURETO TURN OFF GAS TO BOILER For Robertshaw valveFOR AUTOMATIC IGNITION SYSTEMS FLAME FAILURE INSPECTION PROCEDURES BURNERSSAFE SHUT-DOWNTESTS LIMIT ACTION INSPECTIONSCHEDULERAYPAK TUBE CLEANING KIT REPAIRPROCEDURESHEAT EXCHANGER RE-ASSEMBLY SOLUTIONS TROUBLESHOOTING GUIDEPROBLEM IMPORTANT NOTICE10Defective ignition module or defective gas valve ADJUSTMENT/REPLACEMENTOF COMPONENTS DANGER - SHOCK HAZARDREPLACEMENT PARTS LIST RAYPAK, INC 2151 Eastman Avenue Oxnard, CAPage Page Page ADDITIONAL WARRANTY EXCLUSIONS LIMITED PARTS WARRANTYHEAT EXCHANGER WARRANTY PARTS REPLACEMENT
Related manuals
Manual 40 pages 10.3 Kb