Lenox Elite Series XP14 Units HEAT PUMPS, 50677201 Typical Unit Parts Arrangement, Control Panel

Page 3

Typical Unit Parts Arrangement

CONTROL PANEL

CONTACTOR− 1POLE (K1−1)

GROUND

LUG

MUFFLER

CAPACITOR (C12)

DEFROST CONTROL (CMC1)

THERMAL

PROTECTION

SWITCH (S173)

SWITCH

COVER

ONLY ON UNITS

USING EXTERNAL

SWITCH

COMPRESSOR

5−TON UNIT

EXAMPLED HERE

 

DEFROST

TRUE SUCTION

THERMOSTAT (S6)

PORT

 

 

CHECK EXPANSION

REVERSING

VALVE

 

VALVE

 

REVERSING VALVE SOLENOID

CRANKCASE HEATER (−036, −042, −048 AND 060 UNITS ONLY)

LIQUID LINE FILTER DRIER (BI−FLOW)

CHECK EXPANSION VALVE SENSING BULB

LOW PRESSURE

 

 

CRANKCASE HEATER THERMOSTAT (S40)

SWITCH (S87)

 

 

(−036, −042, −048 AND 060 UNITS ONLY)

 

 

 

HIGH PRESSURE SWITCH

 

 

 

(AUTO−RESET) (S4)

 

 

 

VAPOR LINE SERVICE

 

LIQUID LINE

 

VALVE

 

 

 

 

SERVICE VALVE

 

FIELD CONNECTION

 

 

 

 

 

 

FOR VAPOR LINE

 

 

FIELD CONNECTION

(BALL−TYPE −060 ONLY)

 

 

 

 

 

FOR LIQUID LINE SET

 

FIELD CONNECTION FOR VAPOR LINE (ANGLE−TYPE − ALL SIZES EXCEPT −060)

PLUMBING, SWITCHES AND

SENSOR COMPONENTS

Figure 1. Typical Parts Arrangements

Page 3

XP14 SERIES

Image 3
Contents Table of Contents Shipping and Packing ListGeneral TOP View Unit Dimensions Inches mmModel Number Identification 14 −036 − 230 − Side ViewPLUMBING, Switches Sensor Components Typical Unit Parts ArrangementControl Panel Caps and Fasteners Torque Requirements Operating Gauge Set and Service Valves11 12 Method Method 2 Limitations Recovering Refrigerant from Existing System1DISCONNECT Power 3RECOVERING RefrigerantNew Outdoor Unit Placement Detail D Slab Side Mounting Detail a Outside Unit PlacementUsing Feet Extenders Elevated Slab MountingRemoving and Installing Panels Louvered Panel InstallationLouvered Panel Removal Adding Polyol Ester OIL Requirements NEW or Replacement Line SET InstallationUsing Existing Line SET Line Set RequirementsRefrigerant Line SET Alling Horizontal Runs Refrigerant Line SET From Vertical to HorizontalBrazing Connections 2CAP and Core Removal 1CUT and DeburPreparation for Next Step Wrap Service ValvesFlow Nitrogen 6BRAZE Line SET2CONNECT Gauges and Equipment for Flushing Procedure Equalizer Line Installation Installing New Indoor Metering DeviceIndoor Expansion Valve Installation Sensing Bulb InstallationLeak Test Line Set and Indoor Coil Manifold Gauge Set Connections for Leak TestingEvacuating Line Set and Indoor Coil Evacuating Line Set and Indoor Coil24VAC Transformer Size Circuit and Install Disconnect2INSTALL Thermostat ElectricalTypical Unit Wiring Diagram Typical Factory Wiring Copeland Compressor Typical Factory Wiring Interlink Compressor Connect Manifold Gauge SET and WEIGH−IN Charge Unit Start−UpUnit START−UP Leak CHECK, Repair and EvacuateConnections for Optimizing System Charge Calculating System Charge for Outdoor Unit Void of ChargeRefrigerant Charge per Line Set Length Optimizing System Refrigerant Charge Adjusting Indoor AirflowOptimizing Procedure Temperature rise FSATº LIQº SCº = Normal Operating Pressures − Liquid +10 and Vapor +5 Psig CBX32MV−018/024 CX34−31 Defrost Control CMC1 Defrost SystemHomeowner MaintenanceDefrost Control CMC1 Diagnostic LED DealerXP14 Series Sequence of Operation Thermostat Start−Up and Performance ChecklistInstaller City Job Name Job no Date Job Location City