3M 7684-S-8 manual Install Termination, Vinyl Tape Marker

Page 7

6.0Install Termination

6.1Slide the termination body onto the cable and remove core. Pull while unwinding, counter-clockwise, starting

with the loose end (Figure 7). Make sure the termination body (not the core) is butted up to the edge of the vinyl tape marker previously applied (Figure 7).

NOTE: Once the termination body makes contact over the mastic seal area, there is no need to continue supporting the assembly. DO NOT PUSH OR PULL ON THE TERMINATION ASSEMBLY WHILE UNWINDING THE CORE.

Counter-Clockwise

Vinyl Tape Marker

 

NOTE: The material being removed at this step is mixed polymers

and can be recycled with

waste.

Figure 7

6.2Connect ground braid to system ground according to standard practice.

Correct Installation of Termination on Tape Shielded Cable

 

Vi nyl Tape

 

 

Marker

Ridge at End of Cable

 

 

 

Ridge at End

Insulation Shield (Semi-Con)

 

 

 

of High-K Tube

 

 

Semi-Con Insulation Shield

Cable

Envioronmental Top

Stress Controlling Compound

Insulation

Seal

Conductor

 

 

High-K Stress

 

 

 

 

Relief Tube

78-8117-0985-2 Rev C

7

 

Image 7
Contents 7684-S-8 Instructions With High-K Stress ReliefKit Contents Prepare Cable Instructions For Tape Shielded CableInstall Ground Braid Special Note for Cloth or Paper SEMI-CON Insulation Shield Do not Remove Core AT this Time Install Lug or ConnectorVinyl Tape Marker Install TerminationSure to allow for depth of terminal lug Instructions for Wire Shielded Cable6 mm Constant Force Spring Trim Shield Wires This Time Counter-Clockwise Allow for depth of terminal lug Instructions for UniShield Shielded CableRemove semi-conductive jacket to dimension shown in Figure Shield Wire ND Scotch Mastic Strip Install Lug or Connector Vinyl Tape Marker Ridge at End of Cable Thru 30045 One hole Tooling IndexThru 40079 One hole Thru 40178 Two hole Conductor Size AWG & kcmil Stranded Important Notice