3M 7684-S-8 manual Special Note for Cloth or Paper SEMI-CON Insulation Shield

Page 5

3.3Wrap ground braid around cable tape shield one complete wrap, trim excess to prevent overlap and secure in place with constant force spring. Wrap spring in same direction as ground braid (Figure 4). Cinch (tighten) the spring after wrapping the final winding.

3.4Select second Scotch® Mastic Strip 2230 from kit and remove white release liners. Apply a second single wrap of mastic over solder block on ground braid and previously applied mastic (Figure 4). Cut off excess.

Constant Force Spring

 

Tape Shield

 

Ground Braid

 

1ST Scotch® Mastic Strip 2230

Trim

Solder Block

2ND Scotch® Mastic Strip 2230

 

 

Cable

 

Tape

 

Shield

Ground Braid Leg

 

Figure 4

3.5Wrap two highly stretched half-lapped layers of electrical grade vinyl tape around mastic seal, constant force spring and exposed tape shield (Figure 5).

NOTE: Take care not to cover exposed semi-con insulation shield. A minimum of 1" (25 mm) must be exposed.

SPECIAL NOTE FOR CLOTH OR PAPER SEMI-CON INSULATION SHIELD

In cables with cloth or paper semi-conductive shields, it is recommended the shield be over wrapped with one half- lapped layer of highly stretched semi-conductive rubber tape such as Scotch® Electrical Semi-Conducting Tape 13.

Semi-Con

Tape Shield

Constant Force Spring

Two Half-Lapped Layers of Electrical Grade Vinyl Tape

Scotch® Mastic Strip 2230

Vinyl Tape Marker

Figure 5

78-8117-0985-2 Rev C

5

Image 5
Contents 7684-S-8 Instructions With High-K Stress ReliefKit Contents Prepare Cable Instructions For Tape Shielded CableInstall Ground Braid Special Note for Cloth or Paper SEMI-CON Insulation Shield Do not Remove Core AT this Time Install Lug or ConnectorVinyl Tape Marker Install TerminationSure to allow for depth of terminal lug Instructions for Wire Shielded Cable6 mm Constant Force Spring Trim Shield Wires This Time Counter-Clockwise Allow for depth of terminal lug Instructions for UniShield Shielded CableRemove semi-conductive jacket to dimension shown in Figure Shield Wire ND Scotch Mastic Strip Install Lug or Connector Vinyl Tape Marker Ridge at End of Cable Thru 30045 One hole Tooling IndexThru 40079 One hole Thru 40178 Two hole Conductor Size AWG & kcmil Stranded Important Notice