ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES

WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE CONNECTED INTO A PROPERLY GROUNDED THREE- PRONG RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG.

Do not connect broiler to electrical supply until after gas connections have been made.

For OVEN SECTION LIGHTING INSTRUCTIONS see Operations and Maintenance Manual Lighting Instructions Section (F-37403).

LIGHTING INSTRUCTIONS - BROILER SECTIONS

1.Ensure that gas supply to appliance (lower chrome handle) and IR broiler burners (round chrome knobs) are OFF.

2.Turn ON gas supply to appliance.

3.Turn ON gas supply to broiler.

4.Turn ON broiler burner valves to purge air.

5.Turn OFF broiler burner valves and gas supply to broiler.

6.Wait 30 seconds, turn ON gas supply to broiler.

7.Using a taper or wand, light the two pilots.

8.If pilot fails to light, shut off all gas, wait 5 minutes and repeat steps 1-7.

9.Turn broiler burner valves on full to light main burner.

10

Image 10
Contents Series HDR Broilers Important for Your Safety Stop Bolts Unpacking ALL Broiler Models Models Rating Plate LocationModel LocationCombustible NON-COMBUSTIBLE Installation Codes and Standards ALL Broiler Models Broilers Mounted on CastersLeveling and Connecting Manifolds ALL Models Page GAS Connections Testing the GAS Supply SystemFlue Connections Electrical Connections Lighting Instructions Broiler SectionsOperation ControlsMain Gas Valve Before First USEUsing the Broiler CookingCleaning ExteriorService and Parts Information Checks to be Made Before Calling the ServicerLubrication Page Grilloirs HDR DE LA Série Mesures DE Sécurité Importantes Boulons D’ARRÊT Modèles Emplacement DE LA Plaque Signalétique Déballage Tous LES Modèles DE GrilloirsEmplacement Construction Modèle Combustible NON-COMBUSTIBLECodes D’INSTALLATION ET Normes Tous LES Modèles DE Grilloirs Grilloirs SUR RoulettesPage Page Essais DE LA Canalisation DE GAZ Branchement DU GAZRaccordement DU Conduit D’ÉVACUATION Raccordement Électrique Directives D’ALLUMAGE GrilloirsCommandes FonctionnementRobinet de commande du grilloir Avant UNE Première UtilisationCuisson Utilisation DU GrilloirNettoyage Revêtement extérieurLubrification Service DE L’ENTRETIEN ET Pièces DE RechangeAvant D’APPELER LE TECHNICIEN, Vérifier LES Points Suivants