Samsung AR09MSPXAWKNEU Installing and connecting the drain hose, Fire, Install the drain hose

Page 12

Installation

CAUTION

Make sure that the connection parts are not exposed to outside.

Be sure to use insulation tape and a contraction tube made of approved reinforced insulating materials that have the same level of withstand voltage with the power cable. (Comply with the local regulations on extensions.)

WARNING

In case of extending the electric wire, please DO NOT use a round-shaped

pressing socket.

–– Incomplete wire connections can cause electric shock or

a fire.

Step 2.5 Installing and connecting the drain hose

1Install the drain hose.

Drain hose

Assembly pipe

Connection hose

Wall

 

 

Indoor unit

 

 

Drain hose

 

Water

 

 

Slant downwards

Slant upwards

Dipped in water

 

5 cm

 

 

less

Ditch

 

 

Bent

Too small

Too small

 

clearance

clearance

2Pour water into the drain pan. Check whether the hose is well drained.

12English

CAUTION

Make sure that the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Inadequate installation may cause water leakage.

If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

Do not box in or cover the drain hose connection. Drain hose connection must be easily accessible and serviceable.

Step 2.6 Optional: Extending the drain hose

Drain hose (A) Extension drain hose (B)

(A)(B)

Drain hose

Extension drain hose

20 mm or more Foam insulation

Vinyl tape

Image 12
Contents Air conditioner Contents Safety Information on Installation General informationInstall the unit in a place where water can drain smoothly Fires, explosions or injuriesChoosing the installation location PreparationMinimum clearances for the outdoor unit CasesAccessories Accessories in the indoor unit packageUnit mm Accessories in the outdoor unit package Tools General toolsTools for test operation Thermometer Resistance meter Electroscope EnglishDrilling a hole through the wall Taping the pipes, cables, and drain hose Indoor Unit Installation Installation plate Disassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Compression dimension should beInstalling and connecting the drain hose Install the drain hoseOptional Extending the drain hose FireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wall10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Fixing the outdoor unit in placeRefrigerant pipes That the fan can operate correctlyLeave the system in the standby mode Evacuating the airCooling capacity and malfunction. Use a vacuum pump Adding refrigerant Siphon①+②, c Installation Inspection Running the Smart Install modeError between Power cable or communicationMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Performing final check and trial operationPumping down for removing the product Let the compressor run for more than 5 minutesSub PCB installationoptional Attach the Sub PCB to the Case Sub PCBAssemble the Case Sub PCB to the indoor unit DB68-06732A-03