Samsung AR12MSPXASIXEU Drilling a hole through the wall, Taping the pipes, cables, and drain hose

Page 8

Step 1.3 Drilling a hole through the wall

Before fixing the installation plate to a wall and then fixing the indoor unit to the installation plate, a window frame, or a gypsum board, you must determine the position of a hole (with 65 mm inner diameter) through which the pipe bundle (consisting of power and communication cables, refrigerant pipes, and drain hose) will pass and then drill that hole.

1Determine the position of a 65 mm hole in consideration of the possible directions of the pipe bundle and the minimum distances between the hole and the installation plate.

Left

Right

 

Rear right or left

Bottom right

<Possible directions of the pipe bundle>

CAUTION

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

Pipe bundle hole

2Drill the hole.

CAUTION

Be sure to drill only one hole.

Make sure that the hole slants downwards so that the drain hose slants downwards to drain water well.

Wall

Drain hose

Indoor unit

<The hole slants downwards>

Step 1.4 Taping the pipes, cables, and drain hose

1Wrap foam insulation on parts without insulation on the ends of the refrigerant pipes, as shown in the figure. This wrapping minimises condensation problem.

Insulation

Refrigerant pipes

2Wind the refrigerant pipes, power cable, communication cable and drain hose with vinyl tape to make a pipe bundle.

Installation

<Minimum distances between the hole and the

installation plate>

(Unit : mm)

Model

A

B

C

D

 

 

 

 

 

**07*******

 

 

 

 

**09*******

36

120

81

36

**12*******

 

 

 

 

 

 

 

 

 

**18*******

33

110

110

33

**24*******

 

 

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

 

Refrigerant pipes

Installation plate

(assembly pipe)

 

Vinyl tape

 

Power and communication cables

 

(assembly cable)

 

Drain hose

 

8English

Image 8
Contents Air conditioner Contents Safety Information on Installation General informationInstall the unit in a place where water can drain smoothly Fires, explosions or injuries Choosing the installation location Preparation Minimum clearances for the outdoor unit CasesUnit mm AccessoriesAccessories in the indoor unit package Accessories in the outdoor unit package Tools General toolsTools for test operation Thermometer Resistance meter Electroscope EnglishDrilling a hole through the wall Taping the pipes, cables, and drain hoseIndoor Unit Installation Installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Compression dimension should beInstalling and connecting the drain hose Install the drain hoseOptional Extending the drain hose FireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wallWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Fixing the outdoor unit in placeRefrigerant pipes That the fan can operate correctlyCooling capacity and malfunction. Use a vacuum pump Leave the system in the standby modeEvacuating the air Adding refrigerant Siphon①+②, c Installation Inspection Running the Smart Install modeError between Power cable or communicationMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Performing final check and trial operationPumping down for removing the product Let the compressor run for more than 5 minutesAssemble the Case Sub PCB to the indoor unit Sub PCB installationoptionalAttach the Sub PCB to the Case Sub PCB DB68-06732A-03