Samsung AQV18KBAX, AQV12KBAN, AQV12YWAN, AQV09KBAN, AQV09YWAX manual Final Check and Trial Operation

Page 41

Final Check and Trial Operation

To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly.

Check the followings:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (follow the steps below)

1. Press the Power button and check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

2. Press the Mode button to select Cool or Heat mode.

In Cool mode, use Temp hr. + or button and set the temperature at 16°C.

In Heat mode, use Temp hr. + or button and set the temperature at 30°C.

• Approximately 3~5 minutes later, outdoor unit will start to operate and the

Cool or Warm air will blow out.

• After 12 minutes of stationary condition check the indoor unit air treatment.

Cooling mode (indoor unit check) Inlet air temp. - Outlet air temp: From 10°K to 12°K ( indicative delta T)

Heating mode (indoor unit check) Outlet air temp. - Inlet air temp: From 11°K to 14°K (indicative delta T)

In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space.

3.Press the Air swing button and check the following:

The airflow blades work properly.

4.Press the Power button to stop the operation.

• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe

place.

Pump down procedure (when removing the product)

1.Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes.

2. Release the valve caps on High and Low pressure side.

3. Use L wrench to close the valve on the high pressure side.

4. Approximately 2 minutes after, close the valve on the low pressure side.

5. Stop operation of the air conditioner.

6. Disconnect the pipes.

41

ENGLISH

AQV09K&Y@@_Jungfrau_IBIM_E_32448A.indd 41

2011-3-19 15:46:01

Image 41
Contents AQV09K&Y@@JungfrauIBIME32448A.indd 2011-3-19 Contents Important safety symbols and precautions Safety precautionsFollow directions Wall socketFor Using For Cleaning Model RJ Checking before useOperation ranges Display Checking the name of the partsMain parts Remote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperatureUsing the Turbo function Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flowPress the button on the remote controller When the air conditioner is on and in cool/heat modePress the Set/Cancel button to active it ModeSetting the On/Off timer Setting the Current timeFollow the same process for setting on timer and off timer Additional options available in On timer modeUsing the SPi function Using the Smart Saver functionUsing the dlight Cool function Using the Auto Clean functionWhen the air conditioner is turned on Cancel Press the Auto clean button once againYou can reduce the noise generated from an indoor unit UsingAA the Quiet functionCleaning the outdoor unit heat exchanger Cleaning the indoor unitOpening the panel Heat exchangerCleaning the Full HD filter Cleaning the air conditionerRemoving the Full HD filter Dry the Full HD filter in a ventilated areaPeriodical checks Maintaining the air conditionerTroubleshooting All blink Error is indicatedNoise is generated Outdoor unitIncluded Models Remark General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyModel Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When installing 1 outdoor unitSpace Requirements for Outdoor Unit Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Unit mmOptional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCorrect Inclined Pipe 50 Pa. The joint must be accessible and serviceableCracked Outer DiameterDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesDrain hole Drain plug Drain hose Ensure that condensation draining is adequateAdding Refrigerant Gas service port as seen in the pictureIf you use a pipe longer than 5m If you use a pipe shorter than 5m1975 Please fill in with indelible ink the factory refrigerant charge of the product To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Then place the indoor unit on the installation plateFixing the outdoor unit in place 612Final Check and Trial Operation Apply heat to the contraction tube to contract it How to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishWried remote controller, central remote controller etc Sub PCB installationoptional Only for multi systemQuestions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 23.92 Kb Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 43 pages 16.42 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb Manual 23 pages 29.57 Kb Manual 43 pages 11.43 Kb Manual 43 pages 54.66 Kb Manual 45 pages 44.27 Kb Manual 52 pages 58.4 Kb Manual 52 pages 46.07 Kb Manual 1 pages 8.03 Kb Manual 23 pages 40.87 Kb Manual 25 pages 1.01 Kb Manual 23 pages 9.1 Kb Manual 52 pages 18.48 Kb Manual 23 pages 42.75 Kb Manual 23 pages 46.31 Kb Manual 16 pages 35.53 Kb Manual 23 pages 46.82 Kb Manual 42 pages 45.49 Kb Manual 23 pages 57.56 Kb Manual 16 pages 16.35 Kb

AQV18KBAN, AQV09YWAN, AQV09KBAN, AQV18YWAX, AQV09KBAX specifications

Samsung has long been a major player in the electronics market, and its air conditioning units are no exception. Models like AQV12KBAX, AQV12YWAN, AQV18YWAN, AQV09YWAX, and AQV12YWAX showcase the company’s commitment to innovation and user comfort, providing advanced features and superior performance.

The AQV12KBAX is known for its efficient cooling capabilities, leveraging the inverter technology which adjusts the compressor speed based on room temperature, thereby reducing energy consumption and maintaining a consistent temperature. This model also features a quiet operation mode, ensuring that it does not disturb your peace while providing optimal cooling.

Moving to the AQV12YWAN and AQV18YWAN, these models incorporate Samsung’s WindFree cooling technology. This unique feature allows the air conditioner to distribute cool air without the discomfort of direct cold drafts, resulting in a more comfortable indoor environment. The energy-efficient design means that these units can cool larger spaces while utilizing less power, making them an excellent choice for households looking to reduce their energy bills without sacrificing comfort.

The AQV09YWAX and AQV12YWAX models are especially noteworthy for their smart features. They can be integrated with smart home systems, allowing users to control their air conditioning units remotely via smartphone applications. This not only provides convenience but also enables users to monitor energy consumption in real-time, optimizing usage based on their schedules.

All these models are equipped with advanced air purification technology, ensuring that the air circulated is not only cool but also clean. This feature is particularly valuable for those with allergies or respiratory issues, as it helps to filter out dust, pollen, and other airborne pollutants.

In terms of design, Samsung’s air conditioning units are sleek and modern, making them a stylish addition to any room. With their compact size and elegant aesthetics, they blend seamlessly into any interior while providing powerful performance.

In conclusion, Samsung's AQV12KBAX, AQV12YWAN, AQV18YWAN, AQV09YWAX, and AQV12YWAX air conditioning models represent the pinnacle of modern HVAC technology. Their combination of energy efficiency, user-friendly features, and advanced cooling capabilities make them an excellent choice for those seeking reliable climate control solutions. Whether for a small room or a larger living area, Samsung’s air conditioning units deliver comfort, cleanliness, and convenience.