Samsung AQV18YWAX, AQV12KBAN, AQV12YWAN manual Checking before use, Operation ranges, Model RJ

Page 6

Checking before use

Operation ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

Mode

Indoor temperature

Outdoor temperature

Indoor humidity

 

 

 

 

Cooling

16˚C~32˚C

-10˚C~46˚C

Relative humidity 80% or less

 

 

 

 

Heating

27˚C or less

-15˚C~24˚C

-

 

 

 

 

Dry

18˚C~32˚C

-10˚C~46˚C

-

 

 

 

 

If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.

If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of specified capacity according to the using conditions.

Model : RJ

Mode

Indoor

Outdoor

Indoor

If out of conditions

temperature

temperature

humidity

 

 

Cooling

16˚C~32˚C

-5˚C~46˚C

80% or less

Condensation may occur on the indoor unit with risk to have

either water blow off or drop on the floor.

 

 

 

 

Heating

27˚C or less

-15˚C~24˚C

-

Internal protection triggers and the air conditioner will stop.

 

 

 

 

 

Dry

18˚C~32˚C

-5˚C~46˚C

-

Condensation may occur on the indoor unit with risk to have

either water blow off or drop on the floor.

 

 

 

 

The standardizedtemperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.

Maintaining your air conditioner

Internal protections via the unit control system

This internal protection operates if an internal fault occurs in the air conditioner.

Type

Description

 

 

Against cold air

The internal fan will be off to against cold air when the heat pump is heating.

 

 

De-ice cycle

The internal fan will be off to against cold air when the heat pump is heating.

 

 

Anti-protection of

The compressor will be off to protect internal battery when the air conditioner operates

internal battery

in Cool mode.

 

 

Protect compressor

The air conditioner does not start operating immediately to protect the compressor of

the outdoor unit after it has been started.

 

• If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may

have deposited at low temperatures.

The internal fan is switched off automatically and restarted only after the de-ice cycle is completed.

6

AQV09K&Y@@_Jungfrau_IBIM_E_32448A.indd 6

2011-3-19 15:44:36

Image 6
Contents AQV09K&Y@@JungfrauIBIME32448A.indd 2011-3-19 Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesModel RJ Checking the name of the parts Main partsDisplay Checking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressPress the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowPress the Set/Cancel button to active it When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeSetting the Current time Setting the On/Off timerAdditional options available in On timer mode Follow the same process for setting on timer and off timerUsing the Smart Saver function Using the SPi functionWhen the air conditioner is turned on Using the Auto Clean functionUsing the dlight Cool function Cancel Press the Auto clean button once againUsingAA the Quiet function You can reduce the noise generated from an indoor unitOpening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerRemoving the Full HD filter Cleaning the air conditionerCleaning the Full HD filter Dry the Full HD filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Noise is generated Error is indicatedAll blink Outdoor unitGeneral information Included Models RemarkPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel Space Requirements for Outdoor Unit When installing 1 outdoor unitWhen installing more than 1 outdoor unit Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Unit mmTools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Drain hole Drain plug Drain hose Purging the connected pipesConnect a drain hose to the drain plug Ensure that condensation draining is adequateIf you use a pipe longer than 5m Gas service port as seen in the pictureAdding Refrigerant If you use a pipe shorter than 5mPlease fill in with indelible ink  the factory refrigerant charge of the product1975 To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the outdoor unit in place Then place the indoor unit on the installation plateFixing the indoor unit in place 612Final Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishSub PCB installationoptional Only for multi system Wried remote controller, central remote controller etcQuestions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 23.92 Kb Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 43 pages 16.42 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb Manual 23 pages 29.57 Kb Manual 43 pages 11.43 Kb Manual 43 pages 54.66 Kb Manual 45 pages 44.27 Kb Manual 52 pages 58.4 Kb Manual 52 pages 46.07 Kb Manual 1 pages 8.03 Kb Manual 23 pages 40.87 Kb Manual 25 pages 1.01 Kb Manual 23 pages 9.1 Kb Manual 52 pages 18.48 Kb Manual 23 pages 42.75 Kb Manual 23 pages 46.31 Kb Manual 16 pages 35.53 Kb Manual 23 pages 46.82 Kb Manual 42 pages 45.49 Kb Manual 23 pages 57.56 Kb Manual 16 pages 16.35 Kb

AQV18KBAN, AQV09YWAN, AQV09KBAN, AQV18YWAX, AQV09KBAX specifications

Samsung has long been a major player in the electronics market, and its air conditioning units are no exception. Models like AQV12KBAX, AQV12YWAN, AQV18YWAN, AQV09YWAX, and AQV12YWAX showcase the company’s commitment to innovation and user comfort, providing advanced features and superior performance.

The AQV12KBAX is known for its efficient cooling capabilities, leveraging the inverter technology which adjusts the compressor speed based on room temperature, thereby reducing energy consumption and maintaining a consistent temperature. This model also features a quiet operation mode, ensuring that it does not disturb your peace while providing optimal cooling.

Moving to the AQV12YWAN and AQV18YWAN, these models incorporate Samsung’s WindFree cooling technology. This unique feature allows the air conditioner to distribute cool air without the discomfort of direct cold drafts, resulting in a more comfortable indoor environment. The energy-efficient design means that these units can cool larger spaces while utilizing less power, making them an excellent choice for households looking to reduce their energy bills without sacrificing comfort.

The AQV09YWAX and AQV12YWAX models are especially noteworthy for their smart features. They can be integrated with smart home systems, allowing users to control their air conditioning units remotely via smartphone applications. This not only provides convenience but also enables users to monitor energy consumption in real-time, optimizing usage based on their schedules.

All these models are equipped with advanced air purification technology, ensuring that the air circulated is not only cool but also clean. This feature is particularly valuable for those with allergies or respiratory issues, as it helps to filter out dust, pollen, and other airborne pollutants.

In terms of design, Samsung’s air conditioning units are sleek and modern, making them a stylish addition to any room. With their compact size and elegant aesthetics, they blend seamlessly into any interior while providing powerful performance.

In conclusion, Samsung's AQV12KBAX, AQV12YWAN, AQV18YWAN, AQV09YWAX, and AQV12YWAX air conditioning models represent the pinnacle of modern HVAC technology. Their combination of energy efficiency, user-friendly features, and advanced cooling capabilities make them an excellent choice for those seeking reliable climate control solutions. Whether for a small room or a larger living area, Samsung’s air conditioning units deliver comfort, cleanliness, and convenience.