How to connect your extended power cables

Items to prepare

(compressor and insulation tape should be prepared by an installation technician.)

Tools

Crimping plier

Connection sleeve (mm)

Insulation tape

Contraction tube (mm)

Spec

MH-14

20xØ7.0(HxOD)

Width 18mm

50xØ8.0(LxOD)

Shape

 

 

 

 

1.As shown in the figure, peel off the shields from the rubber/wire of the power cable.

- Peel off 20 mm of the wire shields of the tube installed already.

• After peeling off the tube wire, you must insert a contraction tube.

2.Insert both sides of core wire of the power cable into the connection sleeve.

3.Using a compressor, compress the two points and flip it over

and compress another two points in the same location.

-The compression dimension should be 8.0.

-After compressing it, pull both sides of the wire to make sure it is firmly pressed.

4.Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape.

5.Apply heat to the contraction tube to contract it.

(Unit: mm)

Power cable (provided by us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

20

 

20

60 120

180

Wire tube power cable

20

Connection sleeve

Comp. dim.

Compress it 4 times

5mm

Insulation tape

40mm Contraction tube

6. After tube contraction work is completed, wrap it with the

Insulation tape

insulation tape to finish.

 

• In case of extending the electric wire, please DO NOT use a round-shaped pressing socket. - Incomplete wire connections can cause electric shock or a fire.

42

AQV09K&Y@@_Jungfrau_IBIM_E_32448A.indd 42

2011-3-19 15:46:03

Image 42 Contents
AQV09K&Y@@JungfrauIBIME32448A.indd 2011-3-19 Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesModel RJ Checking the name of the parts Main partsDisplay Checking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressPress the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowPress the Set/Cancel button to active it When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeSetting the Current time Setting the On/Off timerAdditional options available in On timer mode Follow the same process for setting on timer and off timerUsing the Smart Saver function Using the SPi functionWhen the air conditioner is turned on Using the Auto Clean functionUsing the dlight Cool function Cancel Press the Auto clean button once againUsingAA the Quiet function You can reduce the noise generated from an indoor unitOpening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerRemoving the Full HD filter Cleaning the air conditionerCleaning the Full HD filter Dry the Full HD filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Noise is generated Error is indicatedAll blink Outdoor unitGeneral information Included Models RemarkPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel Space Requirements for Outdoor Unit When installing 1 outdoor unitWhen installing more than 1 outdoor unit Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Unit mmTools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Drain hole Drain plug Drain hose Purging the connected pipesConnect a drain hose to the drain plug Ensure that condensation draining is adequateIf you use a pipe longer than 5m Gas service port as seen in the pictureAdding Refrigerant If you use a pipe shorter than 5mPlease fill in with indelible ink  the factory refrigerant charge of the product1975 To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the outdoor unit in place Then place the indoor unit on the installation plateFixing the indoor unit in place 612Final Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishSub PCB installationoptional Only for multi system Wried remote controller, central remote controller etcQuestions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 23.92 Kb Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 45 pages 57.87 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb Manual 42 pages 45.49 Kb Manual 43 pages 11.43 Kb Manual 43 pages 54.66 Kb Manual 45 pages 44.27 Kb Manual 23 pages 29.57 Kb Manual 52 pages 58.4 Kb Manual 52 pages 46.07 Kb Manual 1 pages 8.03 Kb Manual 23 pages 40.87 Kb Manual 25 pages 1.01 Kb Manual 23 pages 9.1 Kb Manual 52 pages 18.48 Kb Manual 23 pages 42.75 Kb Manual 23 pages 46.31 Kb Manual 16 pages 35.53 Kb Manual 23 pages 46.82 Kb Manual 16 pages 16.35 Kb