product introduction

Input Port Format Setup

15 input ports are provided by default. For these ports, you can specify if the format of the incoming signal is blocked (NO) or connected (NC) in normal operation. This setting will make all ports operate same regardless of the output status of the input device.

Time Scheduling

You can specify a time range during which a specific operation is performed. You can specify a specific time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time intervals for a day, ranging from Monday to Sunday including holidays. Each time schedule code can produce a single different (or same) holiday code.

Door Open Alarm and Forced Door Open Alarm

The Door Open Alarm function notifies the administrator that the door is still open if a door stays open after the normal door open time and the standby time. (The output signal can be transferred via the output port, data on any abnormal state will be stored in memory, which will be transferred upon request from the PC software. The Forced Door Open Alarm function produces an alert when the door is forced to open and makes an alert again if the door is still open after the timeout.

I/O Settings

This product is equipped with 15 input ports, 12 relay output ports, and 3 TTL output ports. You can use the input ports to receive signals from the Exit button and the fire sensor, and utilize this product to meet various situations such as attaching the door lock to any of the 12 relays. You can also set the output time for these output ports.

Holiday Setup

You can specify a holiday (legal holiday or bi-weekly holiday) excluding Sunday. You can specify up to 100 holidays for a single holiday code. (Access can be permitted only for an allowable time range according to your time schedule setting) A holiday code can be assigned to the time schedule code.

ARM/DISARM

In the condition where the ARM/DISARM code is specified, if you enter the ARM/DISARM code and present the card of the administrator (with master permissions) to the reader, the device triggers the alarm mode where you can control the output signal in sync with the security system. In this mode, all connected readers will not take the card input any further.

Duress Mode

This is used in a situation where you should open the door inevitably by a robber insisting to do so. Open the door

by entering the two-digit duress alarm password and pressing the button before presenting the registered card (or recognizing the card number), in the meantime this forcibly duress situation will be notified to the PC application.

Two Men Operation Mode

This will allow access by visitors only under the control of the visitor guide.

Access will be permitted only if two cards are presented within a specified time (10 seconds).

Dual Door Time Control

This allows you to specify two different settings for the entrance door control time according to the passers-by. However, this can not be enabled with the ARM/DISARM function at the same time.

Data Maintenance

In the event of power failure, the controller retains all card information and the access/alert history (event data) until it is damaged on the memory.

JYou can use the application program (SAMS Basic) to configure all theses settings to your preference.

6_ product introduction

Image 6
Contents Access Control Panel Please visit our websiteSafety information Safety informationImportant Safety Instructions Contents Features Product introductionSettings Input Port Format SetupDoor Open Alarm and Forced Door Open Alarm Holiday SetupWHAT’S Included Main UnitCD Manual Switch System after the initialization Output Relay #1 ~ Board ID SetupSwitch Address Setup 5V for any output occurrence SwitchSignal occurs IndicatoradditionallyInput LED Indicator Buzzer control settingsConnector used to connect to the main board BoardInput port #10 Input port #8Input port #9 Input port #11Cable Selection Host P.CBypass Diode Connection Connecting the Termination Resistor and DiodeTermination Resistor Termination Resistor in RS-485 CommunicationInstallation and external connection EARTH-GROUNDING the Communication CablesPOWER, READER, and I/O Connection Power ConnectionReader Connection Input Connection Exit Button Connection Input #1, Input #3Output Connection DC +12V GNDHost PC Communication Line ConnectionRS-232 Communication Port Connection Check the location of the communication portTX+ RS-422 Communication Port Connection StandaloneHost RX+RS-422 Communication Port Connection Multiple Units TX+ RX+TCP/IP Communication Configuration TCP/IP Communication Port ConnectionHUB TCP / IP TCP/IP ConnectionInitialization Initializing the system using the Initialize switchSwitches simultaneously System InitializationBoard ID Setting You can specify between 0 and 255 for the board IDTroubleshooting TroubleshootingProblem Action Problem When the system is in sync withNo communication is available Product Specifications Product specificationsCorrect disposal of batteries in this product