Samsung AR36HCFUAWKNMG manual PerfoAA rming the gas leak tests, Fixing the indoor unit in place

Page 36

PerfoAA rming the gas leak tests

Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate).

A C

B

To check for gas leaks on the outdoor unit,

Check the valve A and B using a leak detector.

To check for gas leaks on the indoor unit,

Check the flare nut C and D using a leak detector.

D

Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priorly.

 

 

After checking for gas leaks in the system, insulate the pipe, hose and cables.

Insulation

 

Then place the indoor unit on the installation plate.

 

 

1.

To avoid condensation problems, wrap foam insulation (as shown in the figure) on

 

 

a part without insulation on the end of the pipes.

 

 

2.

Wind the pipe, assembly cable and drain hose with vinyl tape.

Pipes

 

3.

Place the bundle (the pipe, assembly cable and drain hose) in the lower part

 

 

 

of the indoor unit carefully so it does not project from the rear of the indoor

Installation

 

 

unit.

 

4.

Hook the indoor unit to the installation plate and move the unit to the right

plate

Connecting

Vinyl tape

pipes

 

and left until it is securely in place.

 

Connecting wires

 

 

 

 

 

• Make sure pipe does not move when you install the indoor unit on

Drain hose

 

 

an installation plate.

 

 

5.Wrap the rest of the pipe with vinyl tape.

6.Attach the pipe to the wall using clamps (optional).

36

SSEC_UMG_IB&IM_DB68-04508A_EN.indd 36

2014-2-10 14:57:04

Image 36
Contents English Contents SafetAA y precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesChecAA king the name of the parts Main partsDisplay ChecAA king the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedUsing the Turbo function Press the Air swing button on the remote controllerAdjusA ting the air flow direction Vertical air flowAA mode Press the button on the remote controllerPress the Time Up or Time Down button to set the time Press the Set button to active it onSettinAA g the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode You can select from Auto/Cool/Dry/Fan/Heat ARHPmodelUsing the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsingAA the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cleaning the indoor unit Cleaning the outdoor unit heat exchangerOpening the panel Heat exchangerCleanAA ing the air conditioner Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outMaintAA aining the air conditioner Periodical checksTroubAA leshooting Flow movement changes. It is normal ConnectionSafety precautions General informationChoosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyChooAA sing the installation location Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberInstallation Smooth the cut edges Cut off the remaining foam insulationAAPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCuttingAA or extending the pipe Outer Diameter Drain hose installation Two hoses are firmly connected, there is no water leakage Hose tight Check for leakage on both side of the drain outletPurging the connected pipes ARHPseriesAdding Refrigerant Add refrigerant charge according to table below30g of refrigerant R-22 must be added for each extra meter If you use a pipe shorter than 4 mPerfoAA rming the gas leak tests Fixing the indoor unit in placeOutdoor unit installed on the wall by rack Fixing the outdoor unit in placeAppropriate support wall or ground Press the Power button and check the following Press the Power button to stop the operationFinalAA Check and Trial Operation Check the followingsApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withInsulation tape to finish TechnAA ical Specifications AR30HCFUAWK/MG AR36HCFUAWK/MGEnglish Questions or COMMENTS? EgyptAir Conditioner