Remote controller display

Turbo indicator

Quiet indicator

(Has no this function)

Smart Saver indicator

On Timer indicator Off Timer indicator

indicator

Heat mode can be selected ARHPSeries.

Operation mode indicator

Low battery indicator

Transmit indicator Air swing indicator Fan speed indicator

Auto (Turbo)

Low

Medium

High

ENGLISH

As to ARHCSeries, don’t operate the air conditioner when the remote controller is set to Heat mode).

Battery changing time

When the battery is exhausted, () will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5V AAA type batteries.

Storing the remote controller

When you do not use the remote controller for long time, remove the batteries from the remote controller and store it.

Inserting the batteries

1.Push the lever as arrow indicates on the rear side of the remote controller and pull up.

2.Insert two AAA batteries.

Check and match the“+”and“-” signs accordingly. Make sure you have inserted the batteries in correct position.

3.Close the cover by place it back to its original position.

You should hear click sound when the cover is locked properly.

• The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps

are in the same space.

• If other electrical products operate by the remote controller, call your nearest contact center.

9

SSEC_UMG_IB&IM_DB68-04508A_EN.indd 9

2014-2-10 14:56:41

Image 9
Contents English Contents Important safety symbols and precautions SafetAA y precautionsFollow directions Wall socketFor Using For Cleaning Operation ranges ChecAA king before useChecAA king the name of the parts Main partsDisplay Remote controller buttons ChecAA king the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperaturePress the Air swing button on the remote controller Using the Turbo functionAdjusA ting the air flow direction Vertical air flowPress the button on the remote controller AA modePress the Time Up or Time Down button to set the time Press the Set button to active it onPress the On Timer/Off Timer button SettinAA g the On/Off timerAdditional options available in On timer mode You can select from Auto/Cool/Dry/Fan/Heat ARHPmodelFrom the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsingAA the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cleaning the outdoor unit heat exchanger Cleaning the indoor unitOpening the panel Heat exchangerCleaning the air filter CleanAA ing the air conditionerRemoving the Air filter Open the panel and put the Air filter outPeriodical checks MaintAA aining the air conditionerTroubAA leshooting Connection Flow movement changes. It is normalGeneral information Safety precautionsInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyChooAA sing the installation location Where sulfide gas existsOutdoor Unit When the air outlet is towards the wall When installing more than 1 outdoor unit Figure Description Top view Side viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberInstallation Cut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe AAPurging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareOuter Diameter CuttingAA or extending the pipeTwo hoses are firmly connected, there is no water leakage Drain hose installationHose tight Check for leakage on both side of the drain outletARHPseries Purging the connected pipesAdd refrigerant charge according to table below Adding Refrigerant30g of refrigerant R-22 must be added for each extra meter If you use a pipe shorter than 4 mFixing the indoor unit in place PerfoAA rming the gas leak testsOutdoor unit installed on the wall by rack Fixing the outdoor unit in placeAppropriate support wall or ground Press the Power button to stop the operation Press the Power button and check the followingFinalAA Check and Trial Operation Check the followingsApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withInsulation tape to finish AR30HCFUAWK/MG AR36HCFUAWK/MG TechnAA ical SpecificationsEnglish Egypt Questions or COMMENTS?Air Conditioner