Samsung AR30HCFUAWKNMG, AR36HCFUAWKNMG manual Fixing the installation plate, Optional accessories

Page 27

Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated Assembly

Insulated Assembly

Insulated Assembly Pipe,

Foam Insulation(1)

PE T3 Foam

 

Drain Plug (1)

Pipe, Ø6.35mm (1)

Pipe, Ø9.52mm (1)

Ø15.88mm (1)

Tube

Vinyl Tapes (2)

ARHP

30

36

30/36

 

Insulation (1)

 

 

Rubber Legs (4)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Drain Hose,

Putty 100g (1)

Screws (6)

length 2m (1)

 

 

 

 

 

ENGLISH

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

 

 

 

• Thermometer

• Resistance Meter

• Electroscope

 

 

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

 

Direction of pipe

 

• Left (B)

 

 

 

• Underside_right (C)

A

 

B

• Rear_right or left (D)

 

 

D

D

C

1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

(Unit : mm)

 

67

156

364

 

34.5

19.5

64.5

Make sure to drill only one hole after choosing the direction of the pipe.

27

SSEC_UMG_IB&IM_DB68-04508A_EN.indd 27

2014-2-10 14:56:58

Image 27
Contents English Contents Wall socket SafetAA y precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges ChecAA king before useChecAA king the name of the parts Main partsDisplay Remote controller buttons ChecAA king the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperatureVertical air flow Using the Turbo functionPress the Air swing button on the remote controller AdjusA ting the air flow directionPress the Set button to active it on AA modePress the button on the remote controller Press the Time Up or Time Down button to set the timeYou can select from Auto/Cool/Dry/Fan/Heat ARHPmodel SettinAA g the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeTurn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is offUsingAA the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Heat exchanger Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelOpen the panel and put the Air filter out CleanAA ing the air conditionerCleaning the air filter Removing the Air filterPeriodical checks MaintAA aining the air conditionerTroubAA leshooting Connection Flow movement changes. It is normalGeneral information Safety precautions a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerChooAA sing the installation location Where sulfide gas existsOutdoor Unit Top view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberInstallation Cut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare AAPurging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter CuttingAA or extending the pipeCheck for leakage on both side of the drain outlet Drain hose installationTwo hoses are firmly connected, there is no water leakage Hose tightARHPseries Purging the connected pipesIf you use a pipe shorter than 4 m Adding RefrigerantAdd refrigerant charge according to table below 30g of refrigerant R-22 must be added for each extra meterFixing the indoor unit in place PerfoAA rming the gas leak testsOutdoor unit installed on the wall by rack Fixing the outdoor unit in placeAppropriate support wall or ground Check the followings Press the Power button and check the followingPress the Power button to stop the operation FinalAA Check and Trial OperationApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withInsulation tape to finish AR30HCFUAWK/MG AR36HCFUAWK/MG TechnAA ical SpecificationsEnglish Egypt Questions or COMMENTS?Air Conditioner